SciELO - Scientific Electronic Library Online

 
vol.109 número3Acúmulo de comprimidos de mesalazina en íleon medio en paciente con enfermedad de CrohnAn immobile postsurgical nasojejunal tube: a case for King Arthur! índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista Española de Enfermedades Digestivas

versión impresa ISSN 1130-0108

Rev. esp. enferm. dig. vol.109 no.3 Madrid mar. 2017

 

PICTURES IN DIGESTIVE PATHOLOGY

 

Long-standing indeterminate biliary stricture with iterative negative tissue sampling revealed as cholangiocarcinoma under SpyGlassTM cholangioscopy

 

 

Andrés Figueroa-Marrero, Carlos M. Chavarría-Herbozo, Carlos de-la-Serna-Higuera and Manuel Pérez-Miranda

Department of Gastroenterology. Hospital Universitario Río Hortega. Valladolid, Spain

 

 

Introduction

Bile duct brush cytology, intraductal biopsy and endoscopy ultrasound-guided fine needle aspiration (EUS-FN) are all used to characterize biliary strictures, with suboptimal sensitivity. Surgical resection without a confirmed malignancy is undesirable. Cholangioscopy with targeted biopsies appears to increase the diagnostic yield in indeterminate biliary strictures (1,2), but it is still considered as optional.

 

Case report

A 59-year-old man was admitted with acute cholangitis. Endoscopic retrograde cholangio-pancreatography (ERCP) revealed a short distal common bile duct stricture. Cytology brushings were obtained, and a biliary 10 F plastic stent was placed (Fig. 1). Over the next six months, four ERCPs were performed due to acute cholangitis episodes caused by stent dysfunction, with repeatedly negative brush cytology. No nodules or masses were seen on spiral computed tomography (CT) or EUS. EUS-FNA samples were obtained from a peripancreatic lymph-node retrieving normal lymphoid cells (Fig. 2). Surgical resection was considered two months after presentation, but eventually rejected in favor of temporary metal fully covered stent therapy. After a three-month period, the metal stent was removed and SpyGlassTM cholangioscopy was performed, revealing an irregular papillary-shaped intraductal lesion with a strong suspicion of malignancy (Fig. 3). Cholangioscopy guided biopsies were obtained. Histology revealed an infiltrative papillary adenocarcinoma. The patient underwent an uneventful Whipple procedure. Histological assessment of the resection specimen showed a T2 cholangiocarcinoma.

 

 

 

 

Discussion

Our case is remarkable because of the negative, repeated efforts at tissue diagnosis which was overcome by cholangioscopy and the lack of tumor spread despite a final diagnosis and treatment eight months after the first presentation. Early use of cholangioscopy may allow the confirmation of malignant indeterminate biliary strictures, thus avoiding the uncertainty of clinical follow-up or surgical resection in the absence of a confirmed malignancy (3).

 

References

1. Ramchandani M, Reddy DN, Gupta R, et al. Role of single-operator peroral cholangioscopy in the diagnosis of indeterminate biliary lesions: A single-center, prospective study. Gastrointest Endosc 2011;74:511-9. DOI: 10.1016/j.gie.2011.04.034.         [ Links ]

2. Manta R, Frazzoni M, Conigliaro R, et al. SpyGlass single-operator peroral cholangioscopy in the evaluation of indeterminate biliary lesions: A single-center, prospective, cohort study. Surg Endosc 2013;27:1569-72. DOI: 10.1007/s00464-012-2628-2.         [ Links ]

3. Woo YS, Lee JK, Oh SH, et al. Role of SpyGlass peroral cholangioscopy in the evaluation of indeterminate biliary lesions. Dig Dis Sci 2014;59:2565-70. DOI: 10.1007/s10620-014-3171-x.         [ Links ]