SciELO - Scientific Electronic Library Online

 
vol.20 número4Virus GB-C: ausencia de asociación con niveles de transaminasas, CD4 y carga vírica en pacientes con sidaSintomatología respiratoria y función pulmonar en población geriátrica de una comunidad rural gallega: un estudio piloto índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

Compartir


Anales de Medicina Interna

versión impresa ISSN 0212-7199

Resumen

RUIZ-GIARDIN, J. M. et al. Utility of anaerobic blood cultures in extrahospitalary bacteremias. An. Med. Interna (Madrid) [online]. 2003, vol.20, n.4, pp.21-24. ISSN 0212-7199.

Objetive: To compare the rentability of anaerobic hemocultures with aerobic cultures in patients suffering bacteremia, trying to analize the rentability of anaerobic cultures.  Methods:  There were analized all the hemocultures taken by medical decision for one month. There were taken three extractions by patient in different venopunctures points. In each extraction was taken 10 ml (5 ml in aerobic bottle, and 5 ml in anaerobic bottle). There were compared microorganism isolated in aerobic bottles and anaerobic bottles. Three physician analized all the clinical dates of the patients with positive hemocultures and ified them as negatives, contaminants and significant.  Results: There were taken hemocultures of 180 patients. There were analyzed 152 hemocultures groups (3 extractions aerobic-anaerobic), without studying 28 owe to not following the study protocol 24 (13.3%) or because of not possibility of studying clinical story 4 (2.2%). Aerobic extractions: Negatives 91 (59.86%), contaminants 36 (23.68%), significant with or without contaminant 25 (16.44%). Anaerobic extractions: Negatives 127 (83.5%), contaminants 2 (1.31%) ; significant with or without contaminant 23 (15.13%). There are 6 (8.6%) significant positive isolated in anaerobic bottles, that were negative in aerobic bottles, and are: 3 E. coli, 1 K. pneumoniae, 1 Peptostreptococcus sp, 1 Bacteroides sp, and over the total significant isolated (31) are the 19.35%. Both anae­robic bacteremias were clinically suspected. Contaminant microorganism more frequently isolated in aerobic bottles was Staphylococcus sp , 25 cases (69.44% of all contaminants). Significant microorganism more frequently isolated was E. coli (in anaerobic bottles too) in 12 cases (38.70%) of all significant isolated, following by Streptococcus pneumoniae  with 4 cases (12.9%).  Conclusions: We recommend collection of one aerobic and one anaerobic blood culture bottle per blood culture set because the global rentability of hemocultures is increased significantly.

Palabras clave : Hemocultures; Bacteremia; Anaerobic.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons