SciELO - Scientific Electronic Library Online

 
vol.17 número3Monitorización del acceso vascular: parámetros convencionales frente a flujo intraaccesoEvolución del peso en pacientes durante el primer año del trasplante renal índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Enfermería Nefrológica

versión On-line ISSN 2255-3517versión impresa ISSN 2254-2884

Resumen

ARAGO SORROSAL, Sergi et al. Adapted automated peritoneal dialysis: an effective, efficient and safe prescription method. Enferm Nefrol [online]. 2014, vol.17, n.3, pp.202-208. ISSN 2255-3517.  https://dx.doi.org/10.4321/S2254-28842014000300007.

The aim of this study is to analyze results obtained following the introduction of the adapted automated peritoneal dialysis, in a group of patients in conventional automated peritoneal dialysis program using bicarbonate-buffered dialysate. Design trial in experimental phase, which was conducted in the months from February and December 2013, in the unit of peritoneal dialysis in the Hospital Clinic of Barcelona. Study subjects were 12 patients, 7 women and 5 men, in conventional automated peritoneal dialysis modality. Mean age 58±12 years (range: 34-71). The study assessed two automated peritoneal dialysis prescriptions. This study was started with conventional dialysis for three months. Then, dialysis prescription was modified, and adapted was applied during same interval of time. And finally, conventional dialysis for three months. The same total volume of dialysate, the same duration, and the same 1,5% glucose bicarbonate buffered dialysate, were prescribed in both modalities. Only dwell time and fill volume were modified, when dialysis modality was changed. All patients, on dry day. Variables at the beginning of the study, and at each change of prescription were seldom monitored. Outcomes for conventional dialysis: Kt/v=2,3±0,2, creatinine clearance=63±8l/week, and ultrafiltration=842±110ml. For dialysis adapted, Kt/v=2,8±0,2, creatinine clearance=74±9l/week, and ultrafiltration=982±123ml. Adapted dialysis allows appropriate treatment efficiency, improves adequacy of dialysis and ultrafiltration parameters; being safe and comfortable for the patient.

Palabras clave : Dialysis prescription; peritoneal dialysis efficiency; adapted; volumes; dwell.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons