SciELO - Scientific Electronic Library Online

 
vol.59 número227Níveis de cálcio e avaliação óssea e de ovos de avestruzes reprodutorasCaracterización de la canal y la carne de la raza bovina menorquina índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Archivos de Zootecnia

versão On-line ISSN 1885-4494versão impressa ISSN 0004-0592

Resumo

MURGAS, L.D.S. et al. Comparative study of different techniques of evaluation of spermatic concentration in swines. Arch. zootec. [online]. 2010, vol.59, n.227, pp.463-466. ISSN 1885-4494.

The precise and accurate determination of the spermatic concentration of the ejaculate is important in the production of insemination doses with a correct number of spermatozoa. The objective of this work was to compare the efficiency of some measurement techniques for spermatic concentration in the semen and to determine prediction equations, establishing a correlation among them. It were collected 93 ejaculations, its spermatic concentration was determined by direct (Neubauer chamber, NC) or indirect (spermdensimeter, SD and spectro-photometer, SP) methods. A randomized block design was utilized, with 93 repetitions and two analysis per experimental unit. Data were submitted to variance analysis, the SNK test was applied to means and the treatments were interrelated by means od adjustment of linear models among results (prediction equation). It was not difference in the determination of the spermatic concentration obtained with SD (361.7 x 106 sptz/ml) and SP (343.7 x 106 sptz/ml), but these values were higher than the NC (245.3 x 106 sptz/ml). The equations obtained were SD= -0.30 [ejaculate volume (in ml)] + 0.61 SP + 213.47 (R2= 0.72) and SD= -0.50 [ejaculate volume (in ml)] + 0.47 NC (R2= 0.7). The SD and SP measurement techniques of the spermatic concentration overestimate values with regard to CN. New research is need to determine the true efficiency of these techniques in farms.

Palavras-chave : Spectrofotometer; Spermdensimeter; Neubauer chamber.

        · resumo em Português     · texto em Português     · Português ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons