SciELO - Scientific Electronic Library Online

 
vol.34 número5Concordancia en pacientes críticos entre las ecuaciones diseñadas para la estimación del filtrado glomerular y el aclaramiento de creatinina en orina de 24hSíndrome de Distrés Respiratorio Agudo, durante la pandemia de Influenza A H1N1 2009 en Ecuador índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Medicina Intensiva

versão impressa ISSN 0210-5691

Resumo

CANABAL BERLANGA, A. et al. Atrioventricular synchrony in patients with pacemaker with VDD mode pacing: A 14-year descriptive study. Med. Intensiva [online]. 2010, vol.34, n.5, pp.303-309. ISSN 0210-5691.

Objective: To analyze the performance of VDD mode pacing in patients with complete AV block with special attention on maintaining AV synchrony. Design: This is a descriptive, retrospective and observational study of a case series. Setting: Intensive Medicine Department of a tertiary Hospital. Patients: All patients with VDD pacemakers implanted between 1994 and 2008. Main measurements: The cause of the rhythm disorder, time of atrioventricular synchrony, cause of its loss, number of pacemaker replacement and reason, age when the first implant was performed, incidence of failure of atrial sensing and atrial fibrillation. We compared patients with atrial fibrillation with the rest who maintained normal atrial activity. Results: A total of 95 patients, 49 (51.6%) males and 46 (48.4%) female with mean age of 77.08±8.37 years, were analyzed. The most common symptom was dizziness and presyncope in 43 cases (45.3%), the most common rhythm disorder was the III AV block with wide QRS with 68 cases (71.6%). Average time of AV synchrony was maintained 73.01±4.2 months with no significant differences between different causes of synchrony loss. At the end of the study, 56 cases remained in AV synchrony (73.3%). Conclusions: The preservation time of AV synchrony is high, the most important causes of loss being entry in atrial fibrillation and atrial infrasensing.

Palavras-chave : VDD pacemaker; Atrioventricular synchrony; Atrioventricular block.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons