SciELO - Scientific Electronic Library Online

 
vol.30 número3Prevalencia de enfermedad cardiovascular en la uremia y relevancia de los factores de riesgo cardiovascularColocación de catéter de diálisis peritoneal por laparoscopia: descripción y resultados de una técnica propia de dos puertos índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Nefrología (Madrid)

versão On-line ISSN 1989-2284versão impressa ISSN 0211-6995

Resumo

MADUELL CANALS, Francisco et al. Guidelines for automated manual infusion: a practical way of prescribing postdilution on-line haemodiafiltration. Nefrología (Madr.) [online]. 2010, vol.30, n.3, pp.349-353. ISSN 1989-2284.

Post-dilution on-line hemodiafiltration (OL-HDF) is the most efficient infusion mode to obtain maximum clearances of uremic toxins, with a recommended manual infusion flow (Qi) of 25% of the blood flow with the main limitation that causes alarms by hemoconcentration throughout the session. Recent technical advances allow automatic prescription of Qi if hematocrit and total protein (TP) values are specified. As these analytical results are not possible to obtain in each dialysis session, a practical way to prescribe Qi is to make an automatic prescription adjusting the hematocrit and total protein values at the beginning of the session to obtain the manual prescription required and we will call it automatic-manual prescription. The aim of this study was to compare manual Qi with automatic-manual Qi in postdilution OL-HDF. 30 patients (16 men and 14 women), 59.9 ± 15 years old, in hemodialysis program for 50.1 ± 67 months were included. Every patient underwent four OL-HDF sessions, two with manual Qi (4008-S and 5008 monitors) and two with automatic-manual Qi (A-M), one with the same Qi and one with manual Qi +20 (A-M+20). The same usual dialysis parameters were maintained: helixone dialyzer, dialysis time of 266 ± 39 minutes, blood flow of 420 ± 36. Recirculation, Kt and intradialysis alarms were measured at each session. No significant differences in the fistula recirculation or dialysis dose measured using Kt. Total infusion volume was 24.9 ± 4 (4008S), 23.4 ± 4 L (5008) with manual Qi, 23.6 ± 4 L (A-M) Qi (NS) and 25.8 ± 5 L (A-M+20). Only 14% of patients had no incidents. The number of alarms was significantly higher with manual prescription 55 alarms with 4008 and 40 with 5008 vs. AM (11) p <0.01) and A-M+20 (16 alarms) We concluded that automatic-manual Qi is a practical way for post-dilutional OL-HDF prescription where the same efficiency and total reinfusion volume with an important reduction of intradialysis alarms are obtained, allowing to rise Qi by 20% without increasing intradialysis alarms.

Palavras-chave : Intradialysis alarms; Automatic; Infusion flow; Postdilution on-line hemodiafiltration.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons