SciELO - Scientific Electronic Library Online

 
vol.79 número7Variación de la ratio longitud axial/radio corneal (LA/RC) con el estado refractivo ocular: Relación con los componentes ocularesLos registros en el trasplante de córnea: evaluación de resultados 1995-2000 índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Archivos de la Sociedad Española de Oftalmología

versão impressa ISSN 0365-6691

Resumo

ALANON FERNANDEZ, FJ; ALANON FERNANDEZ, MA; MARTINEZ FERNANDEZ, A  e  CARDENAS LARA, M. Transcanalicular dacryocystorhinostomy  technique using diode laser. Arch Soc Esp Oftalmol [online]. 2004, vol.79, n.7, pp.325-330. ISSN 0365-6691.

Purpose: To describe the surgical technique and to evaluate the clinical results of carrying out transcanalicular dacryocystorhinostomies using a diode laser (DCR-TC), including the advantages and limitationss of this technique. Methods: 43 DCR-TC were studied and they were analysed using a prospective, interventional, non randomized and non comparative study. We used local and topical anaesthesia in patients with a clinical history of epiphora or dacryocystitis for nasolacrimal obstruction. A diode laser was used to effect a vaporization of the lacrimal sac, osteotomy and vaporization with coagulation of nasal mucosa. The mean duration of surgery was 14 minutes (range 7 to 29 minutes). In all cases, and during a two-month period, bicanalicular intubation was carried out using a silicone tube and prolene filament. Follow-up was between 4 to 38 months. The degree of epiphora was evaluated using the Munk scale and lacrimal permeability was evaluated using Jones I and II tests by direct videoendoscopic control in all cases. Results: 43 DCR-TC were realized, 39 cases are asymptomatic (90.7%). 2 of them (4.65%) had epiphora (degree 2 on the Munk scale) and permeable tract. One case (2.32%) presented lower canaliculi obstruction. One patient showed total osteotomy closing . Conclusions: Transcanalicular dacryocystorhinostomy carried out using a diode laser is a useful method because it does not cause cutaneous scarring, it hardly produces pain and bleeding, it respects the lacrimal pump, it needs less surgical time, it can be carried out in an out-patient surgery and it generates minimal intra and postsurgical morbility.

Palavras-chave : Transcanalicular; dacryocystorhinostomy; diode laser.

        · resumo em Espanhol     · texto em Espanhol

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons