SciELO - Scientific Electronic Library Online

 
vol.42 número6Problemas relacionados con medicamentos que causan ingresos por urgencias en un hospital de alta complejidad índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Farmacia Hospitalaria

versão On-line ISSN 2171-8695versão impressa ISSN 1130-6343

Resumo

VAZQUEZ-BLANCO, Silvia; GONZALEZ-FREIRE, Lara; DAVILA-POUSA, María Carmen  e  CRESPO-DIZ, Carlos. pH determination as a quality standard for the elaboration of oral liquid compounding formula. Farm Hosp. [online]. 2018, vol.42, n.6, pp.221-227.  Epub 09-Nov-2020. ISSN 2171-8695.  https://dx.doi.org/10.7399/fh.10932.

Objective:

pH is a critical factor for all those medications prepared as aqueous liquid forms, because it has an impact on the solubility of the molecule, determining the stability of medications, the biological tolerability of the formulation, and the activity of the molecule. The objective of this study is to determine the optimum pH range for the oral liquid formulations more frequently prepared at the Pharmacy Unit, in order to standardize and incorporate said value into the standard protocols of action as a quality control criterion.

Method:

The study was conducted in three stages. The first stage consisted in a retrospective study of the records of preparation of those oral liquid formulations prepared at least 5 times since January, 2015 to December, 2016, in our Pharmacy Unit; the main value and standard deviation of the pH values recorded for each formulation were calculated. In a second stage, there was a bibliographic search in order to understand the pH for the maximum stability of the molecule, and to confirm if this characteristic was recorded as a requirement for quality control in the procedures described in the formulation guidelines. In the third stage, it was confirmed if the pH values determined coincided with the maximum stability pH described in literature, and acceptance ranges were established.

Results:

In total, 31 formulations were reviewed (14 solutions / 17 suspensions). The maximum stability pH value was known for 19 (61.3%) of the molecules and/or oral liquid formulations evaluated; 15 (78.9%) of these were within this range, and the remaining 4 (21.1%) presented a standard deviation of ± 0.5 regarding the pH value referenced in the bibliography. The pH range for the same standard work procedure ranged between 0.32 and 1.51. An acceptance pH range of ± 0.75 was determined as quality control.

Conclusions:

An optimal pH range has been determined for the 31 oral liquid formulations more widely prescribed in our hospital. This characteristic should be part of the galenic validation for these preparations, as well as of its routine quality control, in order to ensure their quality and efficacy

Palavras-chave : Drug compounding; Drug stability; pH; Quality control; Quality indicator; Pharmaceutical formulary.

        · resumo em Espanhol     · texto em Inglês | Espanhol     · Inglês ( pdf ) | Espanhol ( pdf )