SciELO - Scientific Electronic Library Online

 
vol.21 número3Mapeo de variabilidad sobre prácticas enfermeras relacionadas con el acceso vascular en el entorno de hemodiálisis. Estudio transversal índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Enfermería Nefrológica

versão On-line ISSN 2255-3517versão impressa ISSN 2254-2884

Resumo

JUNQUE JIMENEZ, Anna et al. Evaluation of reliability in functional assessment tools in patients on hemodialysis. Enferm Nefrol [online]. 2018, vol.21, n.3, pp.231-239. ISSN 2255-3517.  https://dx.doi.org/10.4321/s2254-28842018000300004.

Introduction:

It is increasingly common to promote physical exercise programs in hemodialysis patients. The physical condition of patients and the result of these programs with different functional tests can be assessed.

Objective:

To assess the reliability in terms of interobserver reliability of functional capacity and muscle strength measurements in hemodialysis patients.

Material and Method:

30 patients on hemodialysis performed several functional tests in two phases: Short Physical Performance Battery, static monopodal equilibrium, Timed Up and Go, Test Sit-to-stand-To-Sit-5, Sit-to-stand-To-Sit-10, Sit-to-stand-To-Sit-60, strength of triceps sural, 6 minutes walking and dynamometry of the hand.

Results:

The intraclass correlation coefficient for interobserver reliability was for the Sit-to-stand-To-Sit-5 test: 0.779; speed in 4 meters: 0.820; Total score Short Physical Performance Battery: 0.807; Sit-to-stand-To-Sit-10: 0.908; Sit-to-stand-To-Sit-60: 0.865; 6 minutes march: 0.897; Monopodal equilibrium: 0.925; Timed Up and Go: 0.918; Right triceps sural force: 0.702; Left triceps sural force: 0.995; Right hand dynamometry with support: 0.952; Left hand dynamometry with support: 0.897; right hand dynamometry without support: 0.973; left hand dynamometry with support: 0.964.

Conclusions:

The interobserver reliability, in most tests is high, so it can be accepted that the assessment of the patient’s functional status and the results of the programs designed to promote the exercise is carried out by different experienced observers, which would facilitate the follow-up of patients.

Palavras-chave : hemodialysis; ergometric test; capacity to respond; muscular strength; reliability.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )