SciELO - Scientific Electronic Library Online

 
vol.36 número6Análisis de 208 fibrobroncoscopias realizadas en una unidad de cuidados intensivos índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Medicina Intensiva

versión impresa ISSN 0210-5691

Resumen

LUCENA, C.M. et al. Fiberoptic bronchoscopy in a respiratory intensive care unit. Med. Intensiva [online]. 2012, vol.36, n.6, pp.389-395. ISSN 0210-5691.  https://dx.doi.org/10.1016/j.medin.2011.11.004.

Objective: To describe the indications, diagnostic performance and safety of fiberoptic bronchoscopy (FOB) performed in a respiratory intensive care unit (RICU). Design: A prospective, observational study was carried out. Setting: A 6-bed RICU in a tertiary university hospital. Patients: Patients admitted to RICU who required FOB. Interventions: None. Main measurements: FOB indications and complications, endoscopic procedures, time required to perform FOB. Results: Sixty-nine out (23%) of the 297 patients admitted to the RICU underwent a total of 107 FOB. Sixty-eight percent of FOB were performed in patients on mechanical ventilation. FOB was performed for diagnostic and therapeutic purposes in 88 (82%) and 19 cases (18%), respectively. The study of pulmonary infiltrates was the main indication for diagnostic FOB (44 cases; 50%), particularly in immunocompromised patients (24 cases; 27%). In immunocompromised patients the diagnostic performance of FOB was significantly higher than in immunocompetent subjects (48% vs 30%; p<0.01). No major complications were recorded. Only a significant drop in PaO2/FiO2 ratio was observed (182±74 vs 163±79; p<0.005) in patients undergoing bronchoalveolar lavage. Overall mortality in patients in the RICU was 14%. In patients requiring a single FOB procedure, mortality was 25%, versus 45% among those requiring more than one FOB procedure. Conclusions: These results show that FOB is used commonly in the RICU. It is a safe and fast procedure that contributes significantly to clinical management. Patients requiring additional FOB during admission to the RICU show high mortality.

Palabras clave : Fiberoptic bronchoscopy; Intensive care unit; Pulmonary infiltrates; Immunosuppression; Bronchoalveolar lavage.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons