vol.19 número2Evaluación nutricional pre y postoperatoriade los pacientes con megaesófago por enfermedad de ChagasDesarrollo de un cuestionario para la valoración y cuantificación de los hábitos de vida relacionados con el sobrepeso y la obesidad índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

Compartir


Nutrición Hospitalaria

versión On-line ISSN 1699-5198versión impresa ISSN 0212-1611

Resumen

MARSE MILLA, P. et al. Indirect calorimetry in critical ill patients: validity of measurement for ten minutes. Nutr. Hosp. [online]. 2004, vol.19, n.2, pp.95-98. ISSN 1699-5198.

Goal: There are no gold standards on the duration and frequency of the measurement of indirect calorimetry, a fact of importance in daily clinical practice. An assessment of is made of the degree of concordance between energy expenditure at rest (EER) measured over a short interval (10 minutes) versus another prolonged measurement (1 hour). Patients: Sixty critically-ill patients, under sedation and analgesia with connection to mechanical ventilation, were studied. Interventions: EER values were determined by means of a metabolic computer analysis (Engström Eliza) at rest. The reproducibility and the degree of concordance were assessed in the measurements made with both periods. Results: The mean values of the EER determinations at 10 and 60 minutes were 1,818 ± 319 kilocalories/day and 1,815 ± 318 Kcal/day. The limits of the concordance between both times were -101 and +117 kilocalories/day and the correlation was significant (r = 0.98, p < 0.0001). Conclusions: In critically-ill patients under sedation and with mechanical ventilation, the measurement of EER may be taken over short periods of time (10 minutes) providing that baseline examination conditions are met, thus giving greater availability of the resources used to study indirect calorimetry.

Palabras clave : Indirect calorimetry; Measurement times; Critically-ill patients.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons