SciELO - Scientific Electronic Library Online

 
vol.23 número6Capacidad antioxidante de las bebidas infantiles de frutas: influencia del almacenamiento y de la digestión gastrointestinal in vitroPérdidas de nitrógeno y balance nitrogenado en pacientes con infarto maligno de la arteria cerebral media y sometidos a hipotermia moderada (32-33 ºC) índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Nutrición Hospitalaria

versão On-line ISSN 1699-5198versão impressa ISSN 0212-1611

Resumo

ESTEVES DE OLIVEIRA, F. C. et al. Energy expenditure of healthy brazilian adults: a comparison of methods. Nutr. Hosp. [online]. 2008, vol.23, n.6, pp.554-561. ISSN 1699-5198.

There are many available methods to measure the human energy consumption. Due to the high cost and small number of laboratories able to perform it, the direct calorimetry and doubly labeled water technique are rarely used to measure the energy expenditure. As consequence, there is an increase use of the indirect calorimetry and bioelectrical impedance analysis methods by researchers and predictive equations by physicians to calculate the total energy requirements in research and in clinic. Objective: To evaluate the basal energy expenditure (GEB) and total energy expenditure (GET) of healthy subjects comparing results of indirect calorimetry (CI), bioelectrical impedance analysis (BIA) and predictive equations such as estimated energy requirements (EER), Fleish, FAO/WHO/UNU 1985 and 2001. Material and methods: It was evaluated the energy expenditure in 81 subjects of both gender by CI and BIA. Of these, the GEB by predictive equations FAO/WHO/UNU 1985 and 2001 and the GET by EER, Fleisch and FAO/WHO/UNU 1985 and 2001 were calculated. The data was analyzed with the software Sigma Stat for Windows version 2.03 and Dunn's test was used for comparison of mean obtained with methods and equations (p < 0.05). Results: It was verified that 60.5% of the participants were men. The majority of subjects were eutrofic. BIA showed significant differences between men and women. The differences between the values of GEB, obtained by BIA and CI, were statistically significant only for women (p < 0.05) with an underestimation of the GEB results obtained by BIA in relation to those obtained by CI. Significant difference was found between the predictive equations and CI for both sexes, also demonstrating an underestimation of the equations in relation to CI. It was observed an overestimation of GET with the predictive equations of FAO/WHO/UNU/85 and 2001 in relation to EER and Fleisch for both sexes. Conclusion: The estimation of GEB can be carried out by both BIA and CI, although BIA must be used with criteria since it underestimates in a significant way for women. In relation to the predictive equations, overestimation can develop positive energy balance in populations with risks for overweight and obesity. Thus, it is necessary comparisons to identify the limitations of each method.

Palavras-chave : Indirect calorimetry; Bioelectrical impedance analysis; Total energy expenditure; Basal energy expenditure; Predictive equations.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons