SciELO - Scientific Electronic Library Online

 
vol.37 issue6A circadian rhythm-related MTNR1B genetic variant (rs10830963) modulates glucose metabolism and insulin resistance after body weight loss secondary to biliopancreatic diversion surgeryFrequency of sarcopenia, cachexia, and associated factors in patients with chronic kidney disease in dialysis treatment author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Nutrición Hospitalaria

On-line version ISSN 1699-5198Print version ISSN 0212-1611

Abstract

CARRASCO, Fernando et al. Body composition assessment before and after weight loss following a Roux-en-Y gastric bypass. Are bioimpedanciometry estimations reliable?. Nutr. Hosp. [online]. 2020, vol.37, n.6, pp.1150-1156.  Epub Feb 08, 2021. ISSN 1699-5198.  https://dx.doi.org/10.20960/nh.02942.

Introduction:

in patients with severe and morbid obesity it has been observed that bioimpedance (BIA) assessment generates an underestimation of fat mass (FM) and weight loss as FM after bariatric surgery, overestimating the loss of fat-free mass (FFM) and muscle mass.

Objective:

to evaluate the reliability of bioelectrical impedance analysis (BIA) to estimate total body water (TBW), fat-free mass (FFM), fat mass (FM), and its changes after 6 months of a Roux-en-Y gastric bypass (RYGBP), in patients with severe and morbid obesity.

Methods:

thirty-six patients approved for RYGBP were prospectively studied. TBW was measured by deuterium (D), and FM and FFM were calculated. A dual-frequency BIA device (5 and 200 kHz) (Bodystat Dualscan®) was used to estimate FM, FFM, TBW, extracellular water (ECW), intracellular water (ICW), and ECW/ICW ratio.

Results:

before RYGBP, BIA overestimated TBW by 2.6 ± 4.3 L (p = 0.002) and FFM by 3.5 ± 5.7 kg (p = 0.002), and underestimated FM% by 2.98 ± 4.7% (p = 0.002). The ECW/ICW ratio showed a significant and positive correlation with the difference BIA-D for FFM (r = 0.49; p = 0.002). After surgery, the differences between BIA and D were not significant, and the estimation error of FFM did not correlate with the ECW/ICW ratio.

Conclusions:

BIA generates an underestimation of FM as reported in patients with severe and morbid obesity, which is attenuated after weight reduction, underestimating weight loss as FM and overestimating FFM loss. Future research may assess whether these errors are reproduced by other BIA devices.

Keywords : Morbid obesity; Roux-en-Y gastric bypass; Bioelectrical impedance analysis; Total body water.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )