SciELO - Scientific Electronic Library Online

 
vol.81 número9Variación del espesor corneal central en pacientes diabéticos mediante paquimetría ultrasónicaCapacidad diagnóstica del stratus OCT para detectar glaucomas pre-perimétricos índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Archivos de la Sociedad Española de Oftalmología

versão impressa ISSN 0365-6691

Resumo

SIMON, G.. Trabeculoplasty with two different lasers in cats, monkeys and humans: A scanning electron microscopy study. Arch Soc Esp Oftalmol [online]. 2006, vol.81, n.9, pp.527-536. ISSN 0365-6691.

Purpose: To study the structural changes induced by trabeculoplasty with two different lasers (Ti-Sph and argon) and observe the differences between four trabecular meshwork models. Materials and methods: Four different trabecular meshwork (TM) models were used from cats, monkeys, and humans. This study was performed on fresh cadaver eyes («ex vivo») except for the cat in which this study was performed «in vivo». The morphology of the trabecular meshwork was observed by scanning electron microscope (40/100X) after being treated with argon (0.1s/pulse, 600 to 1,000mW, 50µ spot size) and Ti-Sph (7µsg/pulse, 25 to 110mJ,175µm of spot size). The study on cats allowed assessment of the induced effect after 24 hours, and 4 weeks after the treatment on the TM. Typical clinical trabeculoplasty parameters were used for both lasers during this study. Results: The models used in this study were found to be adequate for trabeculoplasty. They exhibited a deep anterior chamber and an accessible TM. The argon laser induced significant changes in the TM in all models studied. The cat model demonstrated TM repair response one month after treatment. For Ti-Sph, high levels of energy (>100mJ) were required to induce significant structural changes in the TM. Conclusion: The IOP reduction effect by argon trabeculoplasty (600/1,000mW) induced structural shrinkage of the collagen in the TM via thermal effects. The Ti-Sph laser works through non-structural mechanisms. At clinical levels (lower than 80mJ), Ti-Sph does not show evidence of TM changes.

Palavras-chave : Scanning electron microscopy; trabeculoplasty; Ti-Sapphire; argon; trabecular meshwork.

        · resumo em Espanhol     · texto em Espanhol     · Inglês ( pdf ) | Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons