SciELO - Scientific Electronic Library Online

 
vol.104 número5Insuflación de CO2 vs. aire en íleo-colonoscopia y en gastroscopia más íleo-colonoscopia: estudio comparativo índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista Española de Enfermedades Digestivas

versión impresa ISSN 1130-0108

Resumen

DUQUE, Gabriela et al. Virtual chromoendoscopy can be a useful software tool in capsule endoscopy. Rev. esp. enferm. dig. [online]. 2012, vol.104, n.5, pp.231-236. ISSN 1130-0108.  https://dx.doi.org/10.4321/S1130-01082012000500002.

Background: capsule endoscopy (CE) has revolutionized the study of small bowel. One major drawback of this technique is that we cannot interfere with image acquisition process. Therefore, the development of new software tools that could modify the images and increase both detection and diagnosis of small-bowel lesions would be very useful. The Flexible Spectral Imaging Color Enhancement (FICE) that allows for virtual chromoendoscopy is one of these software tools. Aims: to evaluate the reproducibility and diagnostic accuracy of the FICE system in CE. Methods: this prospective study involved 20 patients. First, four physicians interpreted 150 static FICE images and the overall agree-ment between them was determined using the Fleiss Kappa Test. Second, two experienced gastroenterologists, blinded to each other results, analyzed the complete 20 video streams. One interpreted conventional capsule videos and the other, the CE-FICE videos at setting 2. All findings were reported, regardless of their clinical value. Non-concordant findings between both interpretations were analyzed by a consensus panel of four gastroenterologists who reached a final result (positive or negative finding). Results: in the first arm of the study the overall concordance between the four gastroenterologists was substantial (0.650). In the second arm, the conventional mode identified 75 findings and the CE-FICE mode 95. The CE-FICE mode did not miss any lesions identified by the conventional mode and allowed the identification of a higher number of angiodysplasias (35 vs 32), and erosions (41 vs. 24). Conclusions: there is reproducibility for the interpretation of CE-FICE images between different observers experienced in conventional CE. The use of virtual chromoendoscopy in CE seems to increase its diagnostic accuracy by highlighting small bowel erosions and angiodysplasias that weren't identified by the conventional mode.

Palabras clave : Capsule endoscopy; Flexible Spectral Imaging Color Enhancement; Erosions; Angiodysplasias.

        · texto en Inglés     · Inglés ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons