SciELO - Scientific Electronic Library Online

 
vol.106 issue1Evaluation of the adequacy and diagnostic accuracy of the histology samples obtained with a newly designed 19-gauge EUS histology needleHow useful is esophageal high resolution manometry in diagnosing gastroesophageal junction disruption: causes affecting this disruption and its relationship with manometric alterations and gastroesophageal reflux author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista Española de Enfermedades Digestivas

Print version ISSN 1130-0108

Abstract

SOLA-VERA, Javier et al. Factors related to the effectiveness of variable stiffness colonoscope: results of a multivariate analysis. Rev. esp. enferm. dig. [online]. 2014, vol.106, n.1, pp.15-21. ISSN 1130-0108.  https://dx.doi.org/10.4321/S1130-01082014000100003.

Background: Various studies and two meta-analysis have shown that a variable stiffness colonoscope improves cecal intubation rate. However, there are few studies on how this colonoscope should be used. Objective: The aim of this study was to identify factors related to the advancement of the colonoscope when the variable stiffness function is activated. Methods: Prospective study enrolling consecutive patients referred for colonoscopy. The variable stiffness colonoscope (Olympus CF-H180DI/L®) was used. We performed univariate and multivariate analyses of factors associated with the success of the variable stiffness function. Results: After the data inclusion period, 260 patients were analyzed. The variable stiffness function was used most in the proximal colon segments (ascending and transverse colon 85 %; descending/sigmoid colon 15.2 %). The body mass index was lower in patients in whom the endoscope advanced after activating the variable stiffness than those in which it could not be advanced (25.9 ± 4.8 vs. 28.3 ± 5.4 kg/m2, p = 0.009). The endoscope advanced less frequently when the stiffness function was activated in the ascending colon versus activation in other segments of the colon (25 % vs. 64.5 % ascending colon vs. other segments; p < 0.05). In the multivariate analysis, only the colon segment in which the variable stiffness was activated was an independent predictor of advancement of the colonoscope. Conclusions: The variable stiffness function is effective, allowing the colonoscope advancement especially when applied in the transverse colon, descending colon and sigmoid. However, when used in the ascending colon it has a lower effectiveness.

Keywords : Endoscopy; Colonoscopy; Variable stiffness.

        · abstract in Spanish     · text in English | Spanish     · English ( pdf ) | Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License