SciELO - Scientific Electronic Library Online

 
vol.15 issue3Comparative study between self-locating peritoneal catheters and Tenckhoff catheters with regard to intraperitoneal displacementAnalysis of renal biopsy complications in renal transplant patients author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Enfermería Nefrológica

On-line version ISSN 2255-3517Print version ISSN 2254-2884

Abstract

GIL GIL, Antonia; GISBERT ROSIQUE, Elena; CASTILLO DIAZ, Miguel  and  BARO SALVADOR, María Eva. Clinical effectiveness in peritoneal catheter exit orifice care. Enferm Nefrol [online]. 2012, vol.15, n.3, pp.194-201. ISSN 2255-3517.  https://dx.doi.org/10.4321/S2254-28842012000300007.

There is a great variety of procedures and methods followed by the professionals who provide peritoneal catheter exit orifice care. We found that all of them had a sound basis and showed effective results. However, we asked ourselves which of them would be the most suitable to use in our unit. We opted to use the recommendations of scientific literature, including variables such as the specific needs of each patient, according to the environmental conditions of our community and the seasons of the year. The main objective of our study was to assess the validity and effectiveness of the protocol we had established for our patients. We carried out a descriptive and longitudinal epidemiological study lasting 2 years and 8 months. We calculated the incidence rate of catheter exit orifice infections and peritonitis per patient and for each of the years of the study (2008-2009-2010). We assessed the result by comparing them with the normality indices set by the Spanish Nephrology Association, in 2007. We broke down the total of infections according to seasons and calculated the percentage. We differentiated between infections caused by gram + and gram-bacteria. The results obtained showed that our protocol is valid and suitable for our patients, obtaining an overall peritonitis incidence rate of 0.72 for every 24 patient-months and an exit orifice infection rate of 0.61 patient-years, both of which are lower than the standard established by the Spanish Nephrology Association (2007). A higher incidence of infections was found in the summer period, specifically 46%. 1% chlorhexidine covers gram+ bacteria, gram- bacteria, spores, viruses and fungi but was found to be most effective with gram+ microorganisms.

Keywords : Exit orifice care; Peritoneal catheter; Chlorhexidine; Exit orifice infection; Peritonitis.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License