SciELO - Scientific Electronic Library Online

 
vol.5 issue1Impact of time of intervention in patients with NSTEMI. The IMPACT-TIMING-GO trial designIschemic postconditioning fails to reduce infarct size in pig models of intermediate and prolonged ischemia author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


REC: Interventional Cardiology

On-line version ISSN 2604-7276Print version ISSN 2604-7306

Abstract

CALVO-FERNANDEZ, Alicia et al. High rate of uncovered struts in latest generation drug-eluting stents with durable, biodegradable polymer or lack of it 1 month after implantation. REC Interv Cardiol ES [online]. 2023, vol.5, n.1, pp.20-28.  Epub Mar 18, 2024. ISSN 2604-7276.  https://dx.doi.org/10.24875/recic.m22000340.

Introduction and objectives:

Delayed vascular healing may induce late stent thrombosis. Optical coherence tomography (OCT) is useful to evaluate endothelial coverage. The objective of this study was to compare stent coverage and apposition in non-complex coronary artery lesions treated with durable polymer-coated everolimus-eluting stents (durable-polymer EES) vs biodegradable polymer-coated everolimus-eluting stents (biodegradable-polymer EES) vs polymer-free biolimus-eluting stents (BES) 1 and 6 months after stent implantation.

Methods:

Prospective, multicenter, non-randomized study that compared the 3 types of DES. Follow-up angiography and OCT were performed 1 and 6 months later. The primary endpoint was the rate of uncovered struts as assessed by the OCT at 1 month.

Results:

A total of 104 patients with de novo non-complex coronary artery lesions were enrolled. A total of 44 patients were treated with polymer-free BES, 35 with biodegradable-polymer EES, and 25 with durable-polymer EES. A high rate of uncovered struts was found at 1 month with no significant differences reported among the stents (80.2%, polymer-free BES; 88.1%, biodegradable-polymer EES; 82.5%, durable-polymer EES; P = .209). Coverage improved after 6 months in the 3 groups without significant differences being reported (97%, 95%, and 93.7%, respectively; P = .172).

Conclusions:

In patients with de novo non-complex coronary artery lesions treated with durable vs biodegradable vs polymer-free DES, strut coverage and apposition were suboptimal at 1 month with significant improvement at 6 months.

Keywords : Optical coherence tomography; Drug-eluting stents; Endothelization; Apposition; Restenosis.

        · abstract in Spanish     · text in English | Spanish     · English ( pdf ) | Spanish ( pdf )