PUNTO DE VISTA

 

Contrastes ultrasónicos versus sonoelastografía en patología digestiva

Ultrasonographic contrast agents versus sonoelastography in digestive diseases

 

 

Modesto Varas Lorenzo1, Fernando Muñoz Agel1, Esteban Cugat Andorra1 y Joan Gornals Soler1,2

1Unidad de Eco-Doppler y Ecoendoscopia, y Cirugía Digestiva. Centro Médico Teknon. Barcelona.
2Unidad de Endoscopia Digestiva (Servicio Aparato Digestivo). Hospital Universitario de Bellvitge. Hospitalet de Llobregat, Barcelona

Dirección para correspondencia

 

 


RESUMEN

Se efectúa una revisión sobre las indicaciones de los contrastes ecográficos (CE), sonográficos o ultrasónicos aplicados a la ultrasonografía convencional (US) y a la ultrasonografía endoscópica (USE), en contraposición a las aplicaciones que tiene hoy en día la sonoelastografía mediante USE.

Palabras clave: Contrastes ecográficos. Ecoendoscopia con contrastes. Elastografía. Sonoelastografía endoscópica. Ecoendoscopia con sonoelastografía. Tumores neuroendocrinos. Cáncer de páncreas. Pancreatitits crónica.


ABSTRACT

A review is made of the indications of ultrasonographic contrast enhancement as applied to conventional ultrasonography and endocopic ultrasonography (EUS) as opposed to the use of EUS-sonoelastography today.

Key words: Ultrasonographic contrast media. Contrast-enhanced echoendoscopy. Elastography. Endoscopic sonoelastography. Echoendoscopy with sonoelastography. Neuroendocrine tumors. Pancreatic cancer. Chronic pancreatitis.


 

Introducción

La ecografía o ultrasonografía (US) digestiva diagnóstica en tiempo real y con escala de grises ha alcanzado una alta resolución, un rendimiento y sensibilidad muy alta en el estudio de las enfermedades biliares, hepatoesplénicas y pancreáticas e incluso del tracto digestivo. Ulteriormente ha sido complementada con el Doppler-color (DC) y con el Power Doppler o Color Angio, y más recientemente con la incorporación en nuestro país de los contrates (CE) (Gómez, 2007) y el 3-D (Muñoz, 2007) (1).

Lo mismo le ha ocurrido a la ecoendoscopia o ultrasonografía endoscópica (USE). La incorporación del color, la sonoelastografía y los contrastes le han conferido una nueva dimensión diagnóstica y sobre todo terapéutica (2).

El color ha posibilitado el mejor estudio de los vasos sanguíneos (la hipertensión portal y las masas).

La sonoelastografía y los contrastes han intentado mejorar el diagnóstico y evitar el estudio histológico mediante PAAF (biopsia virtual) (Figs. 1 y 2).

 

Pero, ¿cuál es el futuro de los CE aplicados a la ultrasonografía (US-CE) o a la ultrasonografía endoscópica (USE-CE) incluyendo la ultrasonografía intraoperatoria (USI-CE)?

Se revisan a continuación el uso de los CE en los tres escenarios diagnósticos: US, USE y USI.

 

Realidad y futuro de la US-CE

Ya son una realidad las siguientes indicaciones:

- Caracterización, delimitación y detección en hígado de masas hepáticas en más del 90% de los casos (3-5); detección de masas en bazo y en el páncreas (6).

- Diagnóstico de hipertensión portal y trombosis portal (100%), incluso maligna (94%).

- Diferenciación entre benignidad y malignidad, en una proporción mayor del 95% (7).

- Estudio de la microcirculación del tracto digestivo: trombosis, isquemia (8) y enfermedad inflamatoria intestinal (EII) (9).

- Control terapia ablativa.

Probablemente en estos dos últimos campos está el futuro:

- Terapia génica.

- Estudios funcionales.

 

Realidad y futuro de la USE-CE

En el estudio de las adenopatías y del tracto digestivo con USE-CE no hay estudios concluyentes.

En el estudio con USE-CE de la patología pancreática es ya una realidad la detección del cáncer de páncreas (CP) (10) inclusive de pequeño tamaño (11).

Aunque el diagnóstico diferencial entre adenocarcinoma y pancreatitis crónica nodular sigue siendo problemático.

La colangiografía retrógrada endoscópica (CREP) y la colangiografía por resonancia magnética (CRM) poseen una sensibilidad de alrededor del 85%, la TC y USE mayor del 90%, USE-PAAF de hasta el 95% (con una media del 86% que baja al 54% cuando existe pancreatitis crónica), con una especificidad que casi alcanza el 100%, mientras que la USE-CE alcanza una sensibilidad del 93% y una especificidad casi del 100% (94%).

¿Y la sonoelastografía con USE?

Los mayoría de los trabajos publicados sobre masas pancreáticas obtienen una sensibilidad alta (87%) y una especificidad media para distinguir entre benignidad y malignidad, excepto un reciente trabajo que publica sensibilidad y especificidad bajas, para el diagnóstico, incluso de adenocarcinoma (50%), recomendando la práctica de PAAF.

Recientes trabajos (12,13) en nuestro país obtienen una sensibilidad del 100% y una especificidad del 78 y 85%. Por lo tanto sería una prueba que puede dar falsos positivos pero no falsos negativos, curiosamente de forma inversa a la PAAF-USE.

La detección de tumores neuroendocrinos (TNE) con CE (Fig. 1) es de casi el 100% (14) (Giovanninni 7/8: 88%) y también de las metástasis de los TNE (15,16).

Con lo cual podrían estar indicados en la detección de tumores en la neoplasia endocrina múltiple (NEM) (tumores pequeños y múltiples).

 

Realidad y futuro de la USI y LAPUS-CE

En 60 pacientes se ha demostrado que los CE son más sensibles que la ultrasonografia intraoperatoria (USI) en la detección de metástasis hepáticas, cambiando el manejo y la resección con intención curativa en el 30% de los casos (17).

Se han obtenido también mejores resultados con los CE-USI que con la USI en la detección de 20 casos de hepatocarcinoma (CHC) injertado en cirrosis hepática (18).

En el futuro será fundamental utilizar los CE antes de una resección hepática y probablemente pancreática.

 

Conclusiones de futuro

1. Detección CHC de pequeño tamaño.
2. Control terapia ablativa.
3. Detección micromestástsis hepáticas inadvertidas, sobre todo de cáncer de colon.
4. Estudio de la microcirculación intestinal (inflamación, isquemia, trombosis).
5. TNE de pequeño tamaño. NEM ?
6. Diagnóstico diferencial CP versus PC. Masas.
7. Contribución a la resección hepática, y posiblemente pancreática ?
8. Terapia génica.
9. Control terapia génica.
10. Otras, como estudios funcionales, etc.

 

Adendum

Aunque los CE no están aprobados en algunos países, han demostrado su impacto (diagnóstico del 90% con un cambio en el manejo del paciente del 17,5 y 15,6%, y hasta del 30% con USI-CE) (17,19,20) y también que son coste efectivos en su aplicación.

No usando radiaciones ionizantes ni poseyendo nefrotoxicidad en más de 23.000 pacientes (escasa morbilidad, sin mortalidad) (21), pueden dar una información diagnóstica comparable a la del TC y RM (22) e inclusive mayor para algunos autores (23), con indicaciones de futuro apasionantes en el campo del diagnóstico e incluso del tratamiento en el aparato digestivo (24-29).

La sonoelastografía (16,30-34) tendrá que mejorar en un futuro (2a o 3a generación) la sensibilidad y especificidad en los tumores pancreáticos, adenopatías y tumores submucosos para poder competir con los contrastes y la PAAF (Tablas I y II).

Una nueva opción sería combinar la sonoelastografia con los contrastes en el diagnóstico diferencial entre pancreatitis crónica y cáncer de páncreas (40) ganando en especificidad y VPP (96%) (Tabla III).

 

 

Dirección para correspondencia:
M.J. Varas Lorenzo.
Unidad de Eco-Doppler y Ecoendoscopia.
Centro Médico Teknon.
C/ Marquesa Vilallonga, 12.
08017 Barcelona
e-mail: varas@dr.teknon.es

Recibido: 28-11-10.
Aceptado: 16-12-10.

 

 

Bibliografía

1. Novedades en ultrasonidos. Rev Esp Enferm Dig 2007;99(Supl.II): 23-27,28-35.         [ Links ]

2. Varas MJ. Ultrasonografía endoscópica, aplicaciones diagnósticas y terapéuticas. Madrid: Ed. Médica Panamericana; 2008.         [ Links ]

3. Ding H, Wang W, Huang B, et al. Imaging of focal liver lesions. Low-mechanical-index real-time ultrasonography with Sonovue. J Ultrasound Med 2005;24:285-97.         [ Links ]

4. Forner A, Rodríguez de Lope C, Reig M, et al. Early diagnosis of primary liver cancer: imaging versus genetics. Rev Esp Enferm Dig 2008;100:423-9.         [ Links ]

5. Piscaglia F, Corradi F, Mancini M, et al. Real time contrast enhanced ultrasonography in detection of liver metastases from gastrointestinal cancer. Cancer 2007;7:171-7.         [ Links ]

6. Kitano M, Kudo M, Maekawa K, et al. Dynamic imaging of pancreatic diseases by contrast enhanced coded phase inversion harmonic ultrasonography. Gut 2004;53:854-9.         [ Links ]

7. Celli N, Gaiani S, Piscaglia F, et al. Characterization of liver lesions by real-time contrast-enhanced ultrasonography. Eur J Gastroenterol Hepatol 2007;19:3-14.         [ Links ]

8. Hamada T, Yamauchi M, Tanaka M, et al. Prospective evaluation of contrast-enhanced ultrasonography with advanced dynamic flow for the diagnosis of intestinal ischaemia. B J Radiology 2007;80:603-8.         [ Links ]

9. Migaleddu V, Scanu AM, Quaia E, et al. Contrast-enhanced ultrasonography evaluation of inflammatory activity in Crohn's disease. Gastroenterology 2009;137:42-52.         [ Links ]

10. Hocke M, Schulze E, Gottschalk P, et al. Contrast-enhanced endoscopic ultrasound in discrimination between focal pancreatitis and pancreatic cancer. W J Gastroenterol 2006;12:246-50.         [ Links ]

11. Sakamoto H, Kitano M, Suetomi Y, et al. Utility of contrast-enhanced endoscopic ultrasonography for diagnosis of small pancreatic carcinomas. Ultrasound Med Biol 2008;34:525-32.         [ Links ]

12. Iglesias-Garcia J, Lariño-Noia J, Domínguez-Muñoz JE. Endoscopic ultrasound elastography in the differential diagnosis of pancreatic solid masses: towards the virtual biopsy. Gastroenterology 2008;134 (Supl.1):A-47.         [ Links ]

13. Iglesias J, Lariño J, Adbulkader I, et al. EUS elastography for the characterization of solid pancreatic masses. Gastrointest Endosc 2009;70:1101-8.         [ Links ]

14. Carrara S, Arcidiacono PG, Mezzi G, et al. Contrast-enhanced endoscopic ultrasound (CE-EUS) in the evaluation of pancreatic masses. JOP. J Pancreas (Online) 2006;7(Supl. 5):558.         [ Links ]

15. Malagò R, D'Onofrio M, Zamboni GA, et al. Contrast-enhanced sonography of nonfunctioning pancreatic neuroendocrine tumors. AJR 2009;192:424-30.         [ Links ]

16. Dietrich CF. Contrast-enhanced low mechanical index endoscopic ultrasound (CELMI-EUS). Endoscopy 2009;41:E43-E-44.         [ Links ]

17. Leen E, Ceccotti P, Moug SJ, et al. Potential value of contrast-enhanced intraoperative ultrasonography during partial hepatectomy for metastases: an essential investigation before resection? Ann Surg 2006;243:236-40.         [ Links ]

18. Lu Q, Luo Y, Yuan CX, et al. Value of contrast-enhanced intraoperative ultrasound in surgery for hepatocellular carcinoma in cirrhosis: 20 cases report. World J Gastroenterol 2008;14:4005-10.         [ Links ]

19. Tombesi P, Catellani M, Abbasciano V, et al. Impact of contrast-enhanced ultrasonography in a tertiary clinical practice. J Ultrasound Med 2008;27:991-2.         [ Links ]

20. Lanka B, Jang H-J, Kim TK, et al. Impact of contrast-enhanced ultrasonography in a tertiary clinical practice. J Ultrasound Med 2007;26:1703-14.         [ Links ]

21. Piscaglia F, Bolondi L. The safety of SonoVue in abdominal applications: retrospective analysis of 23.188 investigations. Ultrasound Med Biol 2006;32:1369-75.         [ Links ]

22. Wilson SR, Greenbaum LD, Goldberg BB. Contrast-enhanced ultrasound: GAT is the evidence and what are the obstacles? AJR 2009; 193:55-60.         [ Links ]

23. Trillaud H, Bruel JM, Valente PJ, et al. Characterization of focal liver lesions with Sonovue R-enhanced sonography: International multicenter-study in comparison to CT and MRI. World J Gastroenterol 2009;15:3748-56.         [ Links ]

24. Dietrich CF, Ignee A, Braden B, et al. Improved differentiation of pancreatic tumors using contrast-enhanced endoscopic ultrasound. Clin Gastroenterol Hepatol 2008;6:590-7.         [ Links ]

25. Klibanov A. Microbubble contrast agents: targeted ultrasound imaging and ultrasoun-assisted drug-delivery applications. Investigate Radiology 2006;41:354-62.         [ Links ]

26. Hernot S, Klibanov AL. Microbubbles in ultrasound-triggered drug and gene delivery. Adv Drug Deliv Rev 2008;60:1153-66.         [ Links ]

27. Bhutani MS. Digital analysis of EUS images: "promising" meted, but is it ready for "prime time"? Gastrointest Endosc 2008;67:868-70.         [ Links ]

28. Ho K-Y. Advanced imaging options: what is available? Gastrointest Endosc 2009;69(2):S68-S70.         [ Links ]

29. Álvarez MV, Varadarajulu S, Napoleón B. EUS contrast agents: what is available, how do they work, and are they effective? Gastrointest Endosc 2009;69(2):S71-S77.         [ Links ]

30. Napoleon B, Alvarez MV, Gincoul R, et al. Contrast-enhanced harmonic endoscopic ultrasound in solid lesions of the pancreas: results of a pilot study. Endoscopy 2010;42:564-70.         [ Links ]

31. Xia Y, Kitano M, Kudo M, et al. Characterization of intra-abdominal lesions of undetermined origin by contrast-enhanced harmonic EUS. Gastrointest Endosc 2010;72:637-42.         [ Links ]

32. Giovannini M. Contrast-enhanced endoscopic ultrasound and elastosonoendoscopy. Best Practice and Research Clin Gastroenterol 2009; 23:767-79.         [ Links ]

33. Hirooka Y, Itoh A, Kawashima H, et al. Diagnosis of pancreatic disorders using contrast-enhanced EUS and endoscopy elastotography. Clin Gastroenterol Hepatol 2009;7:S63-S67.         [ Links ]

34. Iglesias García J, Lariño Noia J, Álvarez Castro A, et al. Second-generation endoscopic ultrasound elastography in the differential diagnosis of solid pancreatic masses. Pancreatic cancer vs inflammatory mass in chronic pancreatitis. Rev esp Enferm Dig 2009;101:723-30.         [ Links ]

35. Giovannini M, Hookey LC, Bories E, et al. Endoscopic ultrasound elastography: the first sep towards virtual biopsy? Preliminary results in 49 patients. Endoscopy 2006;38:344-8.         [ Links ]

36. Giovannini M, Thomas B, Erwan B, et al. Endoscopic ultrasound elastography for evaluation of lymph nodes and pancreatic masses: a multicenter study. World J Gastroenterol 2009;15:1587-93.         [ Links ]

37. Hirche TO, Ignee A, Barrerios AP, et al. Indications and limitations of endoscopic ultrasound elastography for evaluation of focal pancreatic lesions. Endoscopy 2008;40:910-7.         [ Links ]

38. Saftoiu A, Vilmann P, Gorunescu F, et al. Neural network analysis of dinamic sequences of EUS elastography used the differential diagnosis of chronic pancreatitis and pancreatic cancer. Gastrointest Endosc 2008;68:1086-94.         [ Links ]

39. Becker D, Strobel D, Bernatik T, et al. Echo-enhanced color and power-Doppler EUS for discrimination between focal pancreatitis and pancreatic carcinoma. Gastrointest Endosc 2001;53:784-9.         [ Links ]

40. Saftoiu A, Iordache SA, Gheones DI, et al. Combined contrast-enhanced power doppler and real time sonoelastography performed during EUS, used in the differential diagnosis of focal pancreatic masses. Gastrointest Endosc 2010;72:739-42.         [ Links ]

41. Iglesias García J, Lariño Noia J, Domínguez Muñoz JE. Endoscopic ultrasound in the diagnosis and staging of pancreatic cancer. Rev Esp Enferm Dig 2009;101:631-8.         [ Links ]

42. Helmstaedter L, Riemann JF. Pancreatic cancer-EUS and early diagnosis. Langenbecks Arch Surg 2008;393:923-7.         [ Links ]

43. Iglesias Garcia J, Lariño Noia J, Abdulkader I, Forteza J, Domínguez Muñoz JE. Quantitative endoscopic ultrasound elastography: an achurate method for the differentiation of solid pancreatic masses. Gastroenterology 2010; 139: 1172-80.         [ Links ]

44. Fusaroli P, Spada A, Mancino MG, Caletti G. Contrast harmonic Echo-Endoscopic ultrasound improves accuracy in diagnosis of solid pancreatic masses. Clin Gastroenterol Hepatol 2010; 8: 629-34.         [ Links ]

45. Reddy NK, Ioncica AM, Sàtoiu A, Vilmann P, Bhutani MS. Contrast-enhanced endoscopic ultrasonography. World J Gastroenterol 2011;17:42-8.         [ Links ]

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License