Impact of porTable volumetric ultrasound on bladder catheterizations due to urinary retention in an internal medicine unit

David Guadarrama-Ortega1  , Raquel Díaz Díaz2  , María Aránzazu Martín Hernández2  , María Teresa Peces Hernández2  , Jonatan Vallejo Paredes2  , Yolanda Chuvieco González2 

1Research, Innovation and Development Nurse. Research Unit. Alcorcón Foundation University Hospital. Madrid. Spain.

2Assistance Nurse. Alcorcón Foundation University Hospital. Madrid, Spain.

ABSTRACT

Aim

To estimate the impact of the use of porTable bladder volumetric ultrasound on bladder catheterization due to suspicion of urinary retention in an internal medicine unit.

Methodology

Study of retrospective cohorts, comparing the cohort exposed to the availability of bladder ultrasound, with the not exposed the previous year. All records in the Electronic Medical Record (EHR) of short-term permanent bladder catheters in adult patients admitted to the Internal Medicine hospitalization unit of the University Hospital Fundación Alcorcón (HUFA) during the years 2015 and 2016 were analyzed. The urinary retention frequency is estimated as the cause of the catheterization after the device has been incorporated into the unit and compared with the frequency of catheterization during the same period of the previous year in the same unit. It is estimated that the impact of having this device on the urinary retention frequency is the reason for the catheterization.

Results

134 catheters are included in 113 patients, 62 in the group without ultrasound and 72 in the group with ultrasound. The frequency of catheterizations due to retention is reduced from 47.5% to 21.4% after introducing the ultrasound unit into the unit. This represents a 50% reduction (adjusted RR=0.48; CI95%:0.27-0.84, p=0.01) in the frequency of urinary catheterization for suspected urinary retention.

Key words: Catheters, Indwelling; Catheter-Related Infections; Urinary Catheterization; Device Removal; Urinary Retention; Urinary Bladder Diseases; Ultrasonography; Nursing Care

INTRODUCTION

A urinary catheter (UC) is a thin, flexible, hollow tube that can be inserted into the bladder either through the urethra (urethra) or through suprapubic access to drain urine. Bladder catheterization (BC) involves the aseptic placement of a flexible catheter of sterile material that allows urine to be drained from the bladder to the outside through the urethra 1.

In the United States, between 25% and 32% of patients admitted to hospitals are carriers of a UC, either to control urine output or to resolve urinary retention UR2. Furthermore, BC is one of the interventions that generates the most morbidity in the healthcare setting, as it is one of the main causes of nosocomial infections3. It is estimated that around 30% of nosocomial infections are Urinary Tract Infections (UTI), of which 80% are related to urinary catheters3. The risk of suffering a UTI is tripled in patients carrying a UC 4. These infections lead to an increase in hospital stays, increased expenditure and most importantly: health problems and discomfort in patients 3. It is known that the characteristics of BC influence the occurrence of adverse events related to it, it has been shown that the risk of UTIs in patients with UC increases every day that a BC is in place3 and some studies associate catheter clamping with an increase in the rate of UTIs5.

Apart from infections, BC is associated with other types of adverse events such as urinary tract erosions, bleeding, false pathways, and discomfort 2)(3)(5. One of the main problems that appear after removing a bladder catheter, and which most frequently leads to its reinsertion, is UR or bladder dysfunction6. Acute UR is defined as the sudden inability to urinate despite the presence of urine in the bladder and the desire to urinate 7; this situation occurs more frequently in patients who have undergone BC6.

The use of ultrasound to estimate bladder volume has been in the literature since the late 1970s 8)(9. Today, vesical volumetric ultrasound is a reliable and valid method, especially for small volumes, and accepted by patients 10)(11. It is used in 26% of Critical Care Units in the USA 12. It is a method that is useful in the diagnosis of urinary retention after surgery 13, in addition, its use reduces the incidences of UTI14 and according to D'Silva's review suggests that it should be used in patients with suspicion of large post-miction residual volumes15. The use of porTable bladder volumetric ultrasound (PBVU) has, on the other hand, increased the number of successful cases in BC in paediatric patients in the emergency department 16. In our field, it has been studied in surgery patients 17) and in neurological patients 18. It is also a method that has a higher degree of satisfaction among professionals who use it 19.

Nurses play an important role in the insertion and management of UC, so it is essential that their practice reflects the best available evidence, therefore, could the availability of a bladder ultrasound, decrease the frequency of BC due to suspicion of UR?.

The aim of this study is to clarify whether or not it is necessary to have a PBVU device in Internal Medicine hospitalization units.

The main objective of this study is to determine if the availability of a PBVU device used by nurses is related to a decrease in the frequency of BC due to suspicion of UC in adult patients hospitalized in Internal Medicine units.

Secondary objectives:

  • - To determine if PBVU is associated with a decrease in patient hospital stay.

  • - To determine if there are other factors that may be associated with a decrease in BC due to suspicion of UR.

METHODOLOGY

Design

A retrospective cohort study was performed, comparing the cohort exposed to the availability of the PBVU device model BladderScan BVI3000 with the one not exposed the year before to the acquisition of said ultrasound device. The study was carried out in the HB1 Internal Medicine ward of the HUFA.

The study population were adult patients undergoing short-term 20 indwelling BC who were admitted to the Internal Medicine ward.

Subject selection and sample size calculation

The calculation was made using statistical software EPIDAT v. 4.1 21 and considering the most conservative scenario and accepting an alpha risk of 0.05 and a beta risk of 0.2 in a bilateral contrast, a calculation of 124 records was obtained to detect as statistically significant the difference between two proportions, for the exposed group it was expected to be 0.24 and for the unexposed group 0.48. The selection of subjects was carried out by non-probabilistic sampling, the incorporation of patients to the study was done in a chronological consecutive way.

Inclusion criteria

  • Records of adult patients of both sexes who required or carried short-term permanent BC 20 (between 1 and 14 days).

  • Records of patients who had records on the "Probes and Catheters" form of the Electronic Medical Record (EHR).

Exclusion criteria

- Records of patients who have had long-term permanent UC in the previous 30 days.

- Records of patients with long-term permanent UC (15 days or more) were excluded.

- Records of patients who did not have data of adequate quality in the EHR records.

Data collection

For data collection, the EHR database was consulted. After the data collection was completed, they were tabulated in an anonymised and dissociated database in .xlsx format, which was hosted on the centre's internal server, with limited access to the researchers for later analysis. In this way, patient data remained anonymised, in accordance with the Organic Law 15/1999 of 13 December on the protection of personal data 22.

Study variables

The main dependent variable of the study was "BC for suspicion of UR". In order to determine its presence, the indication of BC was checked in the EHR records. The independent variable was the presence during inpatient stay of the PBVU device. For this purpose, it was verified that the date of admission of the patient was later than 16/03/2016, at which time the PBVU device was made available to the nurses of Internal Medicine ward. The secondary variables to be studied were: urinary tract infection (UTI) acquired up to one month after catheterization, length of hospital stay. Demographic variables sex and age, Clinical variables: Indication of catheterization. To analyse whether the degree of complexity of the patients could influence the outcome, the weight of the AP-DRG of the admission in which the catheterizations took place was compared in both groups, as well as the Charlson comorbidity index23.

Statistical analysis

The analysis of the data was carried out with the statistical package for the social sciences SPSS v.22. (24 The sample was described by absolute and relative frequencies for the qualitative variables, mean and standard deviation or by median and interquartile range (IQR), in accordance with the distribution of the data, for the quantitative variables. A descriptive analysis was made of the sample obtained and the baseline situation of both groups.

A univariate analysis was performed to study the differences between the two groups with respect to baseline characteristics (age, sex, Charlson index, previous UTI, catheter type and AP-DRG) and with respect to the main variable “catheterization for suspected UR”. In this analysis, tests of χ2 were used for qualitative variables and to compare quantitative variables between two groups, the t-Student test or non-parametric Mann Whitney's U test was calculated, depending on the distribution of the data. As a main result, it is estimated, by means of modified Poisson regression, the effect of having the PBVU device as a relative risk of catheterization by UR without adjusting and adjusting for other possible related factors. All tests were considered bilateral, statistical significance with a p-value of <0.05 was considered.

Work programme

Once the necessary permissions were obtained from the Research Ethic Committee, a query was made to the HUFA EHR database with the data of the patients who have records from the "Probes and Catheters" form, analysing this form in order to know the percentage of BC that are performed with an indication of "Urinary Retention". The proportions of cases before and after inclusion of the PBVU device were compared.

RESULTS

During the study period, a total of 134 catheterizations were recorded in 113 patients. 53% men. Their mean age was 79.2 (SD 11.8). The median length of hospital stay was 14 days (IQR 6-25). The median of lenght of stay after the last catheterization was 7.9 days (IQR 4-17). When comparing the baseline data by groups, we found only statistically significant differences in the AP-DRG, lower in the cohort with available PBVU device. Table 1

Table 1. Baseline situation of both groups. 

The most frequent indication in the group without PBVU device was suspected UR, with 47.5%; meanwhile, urine output control was the most frequent indication in the group with PBVU, with 45.7% (Table 2).

Table 2. Distribution of BC indication. 

The univariate analysis of the association between the presence of bladder ultrasound and the catheterization for suspicion of UR is shown in Table 3.

Table 3. Univariate analysis for the presence of bladder ultrasound for urinary retention catheterization. 

Other possible factors related to the indication of urinary retention were analyzed and we found that they are older patients, although not statistically significant. We also found that the stay is statistically significant. (Table 4)

Table 4. Univariate analysis for the response variable "BC for suspected UR" 

Due to the fact that the groups were not homogeneous in terms of the average weight of the AP-GRD, and that the age was higher in the group of patients in whom a BC was placed for suspected UR, a multivariate analysis was performed using logistic regression to adjust the effect of PBVU availability on the reduction of suspected UR catheterization. Table 5.

Table 5. Multivariate analysis using logistic regression for the variable BC for suspected UR 

DISCUSSION

Our results indicate a noTable effect of PBVU device implantation on the reduction of BC due to suspected UR. Numerous studies have evaluated the reliability and accuracy of PBVU, but few quantify the effect of having these devices available 15. The fact of having such a device means a reduction, in our case of almost 70% of the risk of BC due to suspicion of UR, which follows the line of the results of Frederickson et al. (25 and not only reduces unnecessary catheterization, but also promotes the reduction of unwanted effects of a BC 26)(27. Its efficacy, combined with its validity and acceptance by patients 17 and its impact on reducing costs associated with catheterization 28 make it a non-invasive rather than an effective alternative to BC in suspected UR episodes, or at least allows us to ensure that this catheterization is necessary. It is also observed that as the age of patients increases, their risk of needing a catheterization for suspected UR increases. This risk is almost identical to that reported by Golubovsky et al. (29 and Lee et al. (30. However, no statistical significance is shown in our regression model. On the other hand, no differences have been found in the incidence of UTI after BC in both groups, since we only have the catheterizations, and not the total number of patients admitted. The results obtained regarding the duration of admission follow the line of previous studies in surgical patients 31)(32.

Since this is an observational and retrospective study, the quality of the information collected in the EHR may be lower than in a prospective study. There may also be a limitation due to the fact that the studied population is very heterogeneous, patients with different pathologies are included. Furthermore, it should be noted that we only have the data recorded in the EHR, leaving out those catheterizations not recorded in the EHR for different reasons.

CONCLUSIONS

Therefore, on the basis of the results obtained and the literature consulted, we can say that the presence in internal medicine units of a PBVU device allows a reduction in the number of BC due to suspicion of UR. It is also observed how, as age increases, the probability of receiving a BC by UR increases. As for hospital stay, we cannot say that it is reduced by the PBVU availability. No other factors were found to be associated with a decrease in bladder catheters due to suspicion of UR.

Ethical and legal aspects

This study has the approval of the Clinical Research Ethics Committee of the HUFA. The proposed research respects the fundamental principles of the Helsinki Declaration. The data protection Organic Law 15/1999, ratified in RD 1720/2007, has been respected, guaranteeing the confidentiality of the information, which was stored anonymously to preserve the anonymity of the patients.

REFERENCES

1. Feneley RCL, Hopley IB, Wells PNT. Urinary catheters: history, current status, adverse events and research agenda. J Med Eng Technol [Internet]. 2015 [cited 2019 Feb 19];39(8):459-70. Available from: http://www.ncbi.nlm.nih.gov/pubmed/26383168 [ Links ]

2. Metersky ML, Eldridge N, Wang Y, Mortensen EM, Meddings J. National trends in the frequency of bladder catheterization and physician-diagnosed catheter-associated urinary tract infections: Results from the Medicare Patient Safety Monitoring System. Am J Infect Control [Internet]. 2017 [cited 2019 Feb 18];45(8):901-4. Available from: http://www.ncbi.nlm.nih.gov/pubmed/28625702 [ Links ]

3. Iacovelli V, Gaziev G, Topazio L, Bove P, Vespasiani G, Agrò EF. Nosocomial Urinary Tract Infections: A Review. Urol J [Internet]. 2014 [cited 2019 Feb 19];81(4):222-7. Available from: http://www.ncbi.nlm.nih.gov/pubmed/25451882 [ Links ]

4. Jackson J, Davies P, Leggett N, Nugawela MD, Scott LJ, Leach V, et al. Systematic review of interventions for the prevention and treatment of postoperative urinary retention. BJS open [Internet]. 2019 [cited 2019 Feb 19];3(1):11-23. Available from: http://www.ncbi.nlm.nih.gov/pubmed/30734011 [ Links ]

5. Wang L-H, Tsai M-F, Han C-YS, Huang Y-C, Liu H-E. Is Bladder Training by Clamping Before Removal Necessary for Short-Term Indwelling Urinary Catheter Inpatient? A Systematic Review and Meta-analysis. Asian Nurs Res (Korean Soc Nurs Sci) [Internet]. 2016 [cited 2017 Oct 24];10(3):173-81. Available from: http://www.ncbi.nlm.nih.gov/pubmed/27692245 [ Links ]

6. Halawi MJ, Caminiti N, Cote MP, Lindsay AD, Williams VJ. The Most Significant Risk Factors for Urinary Retention in Fast-track Total Joint Arthroplasty are Iatrogenic. J Arthroplasty [Internet]. 2019 [cited 2019 Feb 19];34(1):136-9. Available from: http://www.ncbi.nlm.nih.gov/pubmed/30268444 [ Links ]

7. Serlin DC, Heidelbaugh JJ, Stoffel JT. Urinary Retention in Adults: Evaluation and Initial Management. Am Fam Physician [Internet]. 2018 [cited 2019 Feb 19];98(8):496-503. Available from: http://www.ncbi.nlm.nih.gov/pubmed/30277739 [ Links ]

8. Simonelli C, Mayer JW, Messner RP, Wright W. Measurement of critical bladder volume by b-mode ultrasound. Rocky Mt Med J [Internet]. 1979 [cited 2018 May 4];76(6):311. Available from: http://www.ncbi.nlm.nih.gov/pubmed/523899 [ Links ]

9. Brunn J, Ruf G. Sonographische Zystometrie: Ein einfaches Verfahren zur Bestimmung des Restharns. DMW - Dtsch Medizinische Wochenschrift [Internet]. 1980 [cited 2018 May 4];105(43):1501-3. Available from: http://www.ncbi.nlm.nih.gov/pubmed/7428656 [ Links ]

10. Thanagumtorn K. Accuracy of Post-Void Residual Urine Volume Measurement Using an Ultrasound Bladder Scanner among Postoperative Radical Hysterectomy Patients. J Med Assoc Thai [Internet]. 2016 [cited 2019 Feb 19];99(10):1061-6. Available from: http://www.ncbi.nlm.nih.gov/pubmed/29952185 [ Links ]

11. Cho MK, Noh EJ, Kim CH. Accuracy and precision of a new porTable ultrasound scanner, the Biocon-700, in residual urine volume measurement. Int Urogynecol J [Internet]. 2017 [cited 2019 Feb 19];28(7):1057-61. Available from: http://link.springer.com/10.1007/s00192-016-3224-0Links ]

12. Conway LJ, Pogorzelska M, Larson E, Stone PW. Adoption of policies to prevent catheter-associated urinary tract infections in United States intensive care units. Am J Infect Control [Internet]. 2012 [cited 2017 Apr 10];40(8):705-10. Available from: http://linkinghub.elsevier.com/retrieve/pii/S0196655311012569 [ Links ]

13. Daurat A, Choquet O, Bringuier S, Charbit J, Egan M, Capdevila X. Diagnosis of Postoperative Urinary Retention Using a Simplified Ultrasound Bladder Measurement. Anesth Analg [Internet]. 2015 [cited 2018 May 4];120(5):1033-8. Available from: http://www.ncbi.nlm.nih.gov/pubmed/25642660 [ Links ]

14. Alexaitis I, Broome B. Implementation of a Nurse-Driven Protocol to Prevent Catheter-Associated Urinary Tract Infections. J Nurs Care Qual [Internet]. 2014 [cited 2017 Apr 10];29(3):245-52. Available from: http://www.ncbi.nlm.nih.gov/pubmed/24390382 [ Links ]

15. D'Silva KA, Dahm P, Wong CL. Does This Man With Lower Urinary Tract Symptoms Have Bladder Outlet Obstruction? JAMA [Internet]. 2014 [cited 2018 May 4];312(5):535. Available from: http://www.ncbi.nlm.nih.gov/pubmed/25096693 [ Links ]

16. Baumann BM, McCans K, Stahmer SA, Leonard MB, Shults J, Holmes WC. Volumetric bladder ultrasound performed by trained nurses increases catheterization success in pediatric patients. Am J Emerg Med [Internet]. 2008 [cited 2017 Apr 10];26(1):18-23. Available from: http://www.ncbi.nlm.nih.gov/pubmed/18082776 [ Links ]

17. Cabezón Gil P, López Yepes L, Fernández Pérez C, Barreales Tolosa L, Montoya González P, López Timoneda F. Validez y fiabilidad de la ecografía vesical en la estimación no invasiva del volumen de orina en una Unidad de cirugía mayor ambulatoria. Rev Esp Anestesiol Reanim [Internet]. 2009;56(8):479-84. Available from: http://www.sciencedirect.com/science/article/pii/S0034935609704384 [ Links ]

18. Rodrigo-Gil J, Suñer-Soler R, Cruz-Díaz V, Bagot-Prats M, Algans-Coll L, Cepeda-Bautista M, et al. [Care for patients with acute stroke: effectiveness of portable vesical ultrasound imaging in the stroke unit]. Rev Neurol [Internet]. 2012 [cited 2016 May 8];54(3):151-8. Available from: http://www.ncbi.nlm.nih.gov/pubmed/22278891 [ Links ]

19. Baumann BM, McCans K, Stahmer SA, Leonard MB, Shults J, Holmes WC. Caregiver and health care provider satisfaction with volumetric bladder ultrasound. Acad Emerg Med [Internet]. 2007 [cited 2017 Apr 10];14(10):903-7. Available from: http://www.ncbi.nlm.nih.gov/pubmed/17898252 [ Links ]

20. Institute JB. Removal of short-term indwelling urethral catheters. Nurs Stand. 2008;22(22):42-5. [ Links ]

21. Consellería de Sanidade, Xunta de Galicia E Organización Panamericana de la Salud O-O, Universidad CES. Epidat: programa para el análisis epidemiológico de datos. [Internet]. Santiago de Compostela: Xunta de Galicia; 2014. Available from: http://dxsp.sergas.esLinks ]

22. Ley Orgánica 15/1999, de 13 de diciembre, de Protección de Datos de Carácter Personal. [Internet]. Madrid; 1999. Available from: https://www.boe.es/buscar/doc.php?id=BOE-A-1999-23750Links ]

23. Charlson ME, Pompei P, Ales KL, MacKenzie CR. A new method of classifying prognostic comorbidity in longitudinal studies: development and validation. J Chronic Dis [Internet]. 1987 [cited 2018 Aug 30];40(5):373-83. Available from: http://www.ncbi.nlm.nih.gov/pubmed/3558716 [ Links ]

24. IBM Corp. Released 2013. IBM SPSS Statistics for Windows, Version 22.0. Armonk, NY: IBM Corp. [ Links ]

25. Frederickson M, Neitzel JJ, Miller EH, Reuter S, Graner T, Heller J. The implementation of bedside bladder ultrasound technology: effects on patient and cost postoperative outcomes in tertiary care. Orthop Nurs [Internet]. 2000 [cited 2017 Apr 10];19(3):79-87. Available from: http://www.ncbi.nlm.nih.gov/pubmed/11153337 [ Links ]

26. Palese A, Buchini S, Deroma L, Barbone F. The effectiveness of the ultrasound bladder scanner in reducing urinary tract infections: a meta-analysis. J Clin Nurs [Internet]. 2010 [cited 2019 Feb 19];19(21-22):2970-9. Available from: http://www.ncbi.nlm.nih.gov/pubmed/21040003 [ Links ]

27. Niel-Weise BS, van den Broek PJ, da Silva EM, Silva LA. Urinary catheter policies for long-term bladder drainage. Cochrane database Syst Rev. 2012;8:CD004201. [ Links ]

28. Medical Advisory Secretariat. PorTable bladder ultrasound: an evidence-based analysis. Ont Health Technol Assess Ser [Internet]. 2006 [cited 2016 May 8];6(11):13. Available from: http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=3379524&tool=pmcentrez&rendertype=abstract [ Links ]

29. Golubovsky JL, Ilyas H, Chen J, Tanenbaum JE, Mroz TE, Steinmetz MP. Risk factors and associated complications for postoperative urinary retention after lumbar surgery for lumbar spinal stenosis. Spine J [Internet]. 2018 [cited 2018 May 4]; Available from: http://www.ncbi.nlm.nih.gov/pubmed/29447854 [ Links ]

30. Lee KS, Koo KC, Chung BH. Risk and Management of Postoperative Urinary Retention Following Spinal Surgery. Int Neurourol J [Internet]. 2017 [cited 2018 May 4];21(4):320-8. Available from: http://www.ncbi.nlm.nih.gov/pubmed/29298471 [ Links ]

31. Antonescu I, Baldini G, Watson D, Kaneva P, Fried GM, Khwaja K, et al. Impact of a bladder scan protocol on discharge efficiency within a care pathway for ambulatory inguinal herniorraphy. Surg Endosc [Internet]. 2013 [cited 2019 Feb 19];27(12):4711-20. Available from: http://link.springer.com/10.1007/s00464-013-3119-9Links ]

32. Chen S-C, Chen P-Y, Chen G-C, Chuang S-Y, Tzeng I-S, Lin S-K. PorTable Bladder Ultrasound Reduces Incidence of Urinary Tract Infection and Shortens Hospital Length of Stay in Patients With Acute Ischemic Stroke. J Cardiovasc Nurs [Internet]. 2018 [cited 2019 Feb 19];33(6):551-8. Available from: http://www.ncbi.nlm.nih.gov/pubmed/29851660 [ Links ]

Acknowledgements

We would especially like to thank the Internal Medicine Ward of the HUFA for having participated in the realization of the different projects that have led to this article.

Funding: This study is the result of another research project that is financed by the funding for research projects of the Alcorcón Foundation University Hospital in its 2015 edition. (15/63 "Clamp or not clamp. Evaluation of its effects on the removal of bladder catheterisation. Controlled clinical trial"). The PBVU device used for this study could be purchased with this funding.

Received: October 25, 2018; Accepted: March 11, 2019

David Guadarrama-Ortega: dguadarrama@fhalcorcon.es

Creative Commons License Este es un artículo publicado en acceso abierto bajo una licencia Creative Commons