SciELO - Scientific Electronic Library Online

 
vol.5 número4Hemoptisis masiva. Embolización selectiva de fístula de arteria bronquial a arteria pulmonar izquierda. ResoluciónFragmento de guía coronaria insospechado índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


REC: Interventional Cardiology

versão On-line ISSN 2604-7276versão impressa ISSN 2604-7306

REC Interv Cardiol ES vol.5 no.4 Madrid Out./Dez. 2023  Epub 04-Mar-2024

https://dx.doi.org/10.24875/recic.m23000378 

Images in cardiology

New TAVI technique for difficult valve crossing

José M de la Torre-Hernández  *  , Gabriela Veiga-Fernández  , Sergio Barrera  , Fermín Sainz-Laso  , Dae-Hyun Lee  , Tamara García-Camarero 

Servicio de Cardiología, Hospital Universitario Marqués de Valdecilla, Instituto de Investigación Sanitaria IDIVAL, Santander, Spain

This is the case of an 83-year-old man with symptomatic, severe aortic valve stenosis referred for transcatheter aortic valve implantation (TAVI). The echocardiogram revealed the presence of a severely calcified stenotic aortic valve (0.6 cm2) with bicuspid anatomy (figure 1A). The computed tomography scan revealed an Agatston calcium score of 17 727 (figure 1B), a 30 mm aortic annulus diameter, and dilated aortic root and aortic angulation > 70º (figure 1C). Aortography was performed (figure 1D).

Figure 1. 

Crossing the aortic valve with a guidewire for 60 min using catheters of various curves/sizes and several types of guidewires (with or without J-shaped tip, whether hydrophilic or not) was attempted by 2 highly skilled operators. Strategy, then, changed and a XB4 6F left coronary guide catheter (Cordis, United States) was used to manipulate a 0.014 inch hydrophilic Pilot 50 intracoronary guidewire (Abbott, United States) that easily crossed the aortic valve (figure 1E). A 6-Fr guide catheter extension system (Deeper, IHT-Cordynamic, Spain) was mounted on the wire and advanced to the left ventricular apex (figure 1F). Afterwards, the intracoronary guidewire was replaced by a 0.035 inch extra-stiff guidewire by removing both the guide and extension catheter systems (figure 1G). This original new approach took just 5 min.

The impossibility of crossing the aortic valve with a guidewire is rare. In our case the difficulty was due to a severely stenotic valve with massive calcification, bicuspid morphology, horizontal aorta, and dilatation of both the aortic root and the annulus.

This case is a truly original and novel technique, simple and safe, to achieve the guidewire crossing of a very stenotic aortic valve with a complex anatomy. This technique illustrates the cross-over use of coronary and structural interventional tools to solve complex problems.

Consent was obtained from the patient for the publication of this case.

FUNDINGNone reported.

Received: February 16, 2023; Accepted: March 24, 2023; pub: May 12, 2023

*Corresponding author. E-mail addresses: josemariadela.torre@scsalud.es; chematorre60@gmail.com (J.M. de la Torre-Hernández).

CONFLICTS OF INTEREST

J. M. de la Torre-Hernández is editor-in-chief of REC: Interventional Cardiology. The journal’s editorial procedure to ensure impartial handling of the manuscript has been followed. The other authors do not declare any conflict.

AUTHORS’ CONTRIBUTIONS

All authors contributed to data collection, drafting, review, and approval of the manuscript.

Creative Commons License Sociedad Española de Cardiología. Publicado por Permanyer Publications. Este es un artículo open access bajo la licencia CC BY-NC-ND 4.0