SciELO - Scientific Electronic Library Online

 
vol.35 issue6Drug-related acute renal failure in hospitalised patientsDevelopment of certified environmental management in hospital and outpatient haemodialysis units author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Nefrología (Madrid)

On-line version ISSN 1989-2284Print version ISSN 0211-6995

Abstract

ALBALATE RAMON, Marta et al. What is the optimum dialysate flow in post-dilution online haemodiafiltration?. Nefrología (Madr.) [online]. 2015, vol.35, n.6, pp.533-538. ISSN 1989-2284.  https://dx.doi.org/10.1016/j.nefro.2015.04.007.

Introduction: In post-dilution online hemodiafiltration (OL-HDF), the only recommendation concerning the dialysate, or dialysis fluid, refers to its purity. No study has yet determined whether using a high dialysate flow (Qd) is useful for increasing Kt or ultrafiltration-infusion volume. Objective: Study the influence of Qd on Kt and on infusion volume in OL-HDF. Material and methods: This was a prospective crossover study. There were 37 patients to whom 6 sessions of OL-HDF were administered at 3 different Qds: 500, 600 and 700 ml/min. A 5008® monitor was used for the dialysis in 21 patients, while an AK-200® was used in 17. The dialysers used were: 20 with FX 800® and 17 with Polyflux-210®. The rest of the parameters were kept constant. Monitor data collected were effective blood flow, effective dialysis time, final Kt and infused volume. Results: We found that using a Qd of 600 or 700 ml/min increased Kt by 1.7% compared to using a Qd of 500 ml/min. Differences in infusion volume were not significant. Increasing Qd from 500 ml/min to 600 and 700 ml/min increased dialysate consumption by 20% and 40%, respectively. Conclusions: With the monitors and dialysers currently used in OL-HDF, a Qd higher than 500 ml/min is unhelpful for increasing the efficacy of Kt or infusion volume. Consequently, using a high Qd wastes water, a truly important resource both from the ecological and economic points of view.

Keywords : Dialysate flow rate; Kt; Hemodiafiltration on-line; Infusion volume.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License