vol.31 issue3Can we improve the birth weight prediction?: the effect of normal BMI using a multivariate modelCross-sectional study to evaluate the associated factors with differences between city and districts secondary school students of the southeast of Spain (Murcia) for their adherence to the Mediterranean diet author indexsubject indexarticles search
Home Pagealphabetic serial listing  

My SciELO

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Nutrición Hospitalaria

On-line version ISSN 1699-5198Print version ISSN 0212-1611

Nutr. Hosp. vol.31 n.3 Madrid Mar. 2015

https://dx.doi.org/10.3305/nh.2015.31.3.8173 

ORIGINAL / Valoración nutricional

 

Assessment of the reliability and consistency of the "Malnutrition Inflammation Score" (MIS) in Mexican adults with chronic kidney disease for diagnosis of protein-energy wasting syndrome (PEW)

Evaluación de fiabilidad y consistencia de la herramienta "malnutrition inflammation score (MIS)" en adultos mexicanos con enfermedad renal crónica para diagnóstico del sindrome de desgaste proteínico energético (DPE)

 

 

Ailema Janeth González-Ortiz1,2, Celene Viridiana Arce-Santander2, Olynka Vega-Vega2, Ricardo Correa-Rotter2 and Maria Angeles Espinosa-Cuevas2,3

1Fac. de Medicina, Universidad Nacional Autónoma de México.
2Departamento de Nefrología y Metabolismo Mineral, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán.
3Departamento de Atención a la Salud, Universidad Autónoma Metropolitana-Xochimilco, México DF. México.

 

 


ABSTRACT

Background: The protein-energy wasting syndrome (PEW) is a condition of malnutrition, inflammation, anorexia and wasting of body reserves resulting from inflammatory and non-inflammatory conditions in patients with chronic kidney disease (CKD).One way of assessing PEW, extensively described in the literature, is using the Malnutrition Inflammation Score (MIS).
Objective: To assess the reliability and consistency of MIS for diagnosis of PEW in Mexican adults with CKD on hemodialysis (HD).
Methods: Study of diagnostic tests. A sample of 45 adults with CKD on HD were analyzed during the period June-July 2014.The instrument was applied on 2 occasions; the test-retest reliability was calculated using the Intraclass Correlation Coefficient (ICC); the internal consistency of the questionnaire was analyzed using Cronbach's α coefficient. A weighted Kappa test was used to estimate the validity of the instrument; the result was subsequently compared with the Bilbrey nutritional index (BNI).
Results: The reliability of the questionnaires, evaluated in the patient sample, was ICC=0.829. The agreement between MIS observations was considered adequate, κ = 0.585 (p <0.001); when comparing it with BNI, a value of κ = 0.114 was obtained (p <0.001).In order to estimate the tendency, a correlation test was performed. The r2 correlation coefficient was 0.488 (P <0.001).
Conclusion: MIS has adequate reliability and validity for diagnosing PEW in the population with chronic kidney disease on HD.

Key words: Protein energy wasting. Nutritional assessment. Dialysis. Validation. Reliability.


RESUMEN

Antecedentes: El sindrome de desgaste proteinico-energetico (DPE) se refiere a una condicion de desnutricion, inflamacion, anorexia, y emaciacion de reservas corporales resultante de las condiciones inflamatorias y no inflamatorias que prevalecen en pacientes con enfermedad renal cronica (ERC).Una forma ampliamente descrita en la literatura para evaluar el DPE es el Malnutrition Inflamation Score (MIS).
Objetivo: Valorar la fiabilidad y consistencia del MIS en adultos mexicanos con ERC en Hemodialisis (HD) para Diagnostico de DPE.
Metodos: Estudio de pruebas diagnosticas. Se analizo una muestra de 45 adultos con ERC en HD, Durante el periodo Junio-Julio 2014. El instrumento se aplico en 2 ocasiones, la fiabilidad test-retest se calculo mediante el Coeficiente de correlacion Intraclase (CCI), la consistencia interna del cuestionario se analizo mediante el Coeficiente α de Cronbach. Se calculo una prueba de Kappa ponderada para estimar la validez del instrumento, posteriormente se comparo con el indice nutricional de Bilbrey (IB).
Resultados: La fiabilidad entre cuestionarios valorada en la muestra de pacientes fue de CCI = 0.829. La concordancia entre observaciones MIS es considerada como adecuada κ = 0.585 (p<0.001), al compararlo con IB se obtuvo un valor de κ = 0.114 (p<0.001). Para conocer la tendencia se realizo una correlacion r2=0.488 (P <0.001).
Conclusion: El MIS presenta una adecuada fiabilidad y validez para diagnosticar DPE en la poblacion con enfermedad renal cronica en HD.

Palabras clave: Desgaste proteínico energético. Evaluación nutricional. Diálisis. Validación. Fiabilidad.


 

 

http://scielo.isciii.es/pdf/nh/v31n3/48originalvaloracionnutricional10.pdf