SciELO - Scientific Electronic Library Online

 
vol.79 issue7Changes in axial lenght/corneal radius ratio (AL/CR) according to refractive state of the eye: Relationship with ocular componentsCorneal graft data collection: evaluation of results 1995-2000 author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Archivos de la Sociedad Española de Oftalmología

Print version ISSN 0365-6691

Abstract

ALANON FERNANDEZ, FJ; ALANON FERNANDEZ, MA; MARTINEZ FERNANDEZ, A  and  CARDENAS LARA, M. Transcanalicular dacryocystorhinostomy  technique using diode laser. Arch Soc Esp Oftalmol [online]. 2004, vol.79, n.7, pp.325-330. ISSN 0365-6691.

Purpose: To describe the surgical technique and to evaluate the clinical results of carrying out transcanalicular dacryocystorhinostomies using a diode laser (DCR-TC), including the advantages and limitationss of this technique. Methods: 43 DCR-TC were studied and they were analysed using a prospective, interventional, non randomized and non comparative study. We used local and topical anaesthesia in patients with a clinical history of epiphora or dacryocystitis for nasolacrimal obstruction. A diode laser was used to effect a vaporization of the lacrimal sac, osteotomy and vaporization with coagulation of nasal mucosa. The mean duration of surgery was 14 minutes (range 7 to 29 minutes). In all cases, and during a two-month period, bicanalicular intubation was carried out using a silicone tube and prolene filament. Follow-up was between 4 to 38 months. The degree of epiphora was evaluated using the Munk scale and lacrimal permeability was evaluated using Jones I and II tests by direct videoendoscopic control in all cases. Results: 43 DCR-TC were realized, 39 cases are asymptomatic (90.7%). 2 of them (4.65%) had epiphora (degree 2 on the Munk scale) and permeable tract. One case (2.32%) presented lower canaliculi obstruction. One patient showed total osteotomy closing . Conclusions: Transcanalicular dacryocystorhinostomy carried out using a diode laser is a useful method because it does not cause cutaneous scarring, it hardly produces pain and bleeding, it respects the lacrimal pump, it needs less surgical time, it can be carried out in an out-patient surgery and it generates minimal intra and postsurgical morbility.

Keywords : Transcanalicular; dacryocystorhinostomy; diode laser.

        · abstract in Spanish     · text in Spanish

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License