COLOME-CAMPOS, J. et al. Anatomical repercussion on the zonular apparatus after a capsular tension ring insertion in swine eyes. Arch Soc Esp Oftalmol [online]. 2008, vol.83, n.10, pp.589-593. ISSN 0365-6691.
Purpose: To carry out an experimental and descriptive study that exhibits the anatomical repercussions on the zonular apparatus after a capsular tension ring (CTR) is inserted. Methods: CTRs were inserted in five swine eyes (four with forceps, one with an injector). Two additional eyes were left untouched for control purposes. The integrity of the suspensory ligament was examined by scanning electron microscopy. Results: We did not observe alterations in the integrity of the zonular apparatus. The suspensory ligaments adopted a new fold configuration. Conclusions: CTR insertion is a safe therapeutic tool to maintain the integrity of the lens zonules in elastic, large diameter capsular bags.
Keywords : Capsular tension ring; lens zonules; clear lens extraction; zonular dialysis.