SciELO - Scientific Electronic Library Online

 
vol.84 issue12Morphological macular changes after cataract surgery: risk factorsPeripheral vitreoretinal traction exploration by Staurenghi 230 lens and HRA-II author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Archivos de la Sociedad Española de Oftalmología

Print version ISSN 0365-6691

Abstract

LOPEZ-PENA, M.J. et al. Relationship between standard automated perimetry and optic nerve head topography performed with the Heidelberg retina tomograph. Arch Soc Esp Oftalmol [online]. 2009, vol.84, n.12, pp.611-624. ISSN 0365-6691.

Purpose: To determine the correlations between optic nerve head (ONH) parameters measured with the Heidelberg Retina Tomograph (HRT), and the main outcomes of standard automated perimetry (SAP) in normal, ocular hypertensive, glaucoma suspects and glaucomatous subjects. Methods: Four hundred and twenty-three patients were enrolled in the study and classified into four groups depending on baseline intraocular pressure, optic nerve head morphology, and SAP results: 87 normal eyes, 192 ocular hypertensive eyes, 70 glaucoma suspects and 74 glaucomatous eyes. In the different diagnostic groups, Pearson's correlation coefficients were calculated between ONH parameters and mean deviation, pattern standard deviation (PSD), number of altered points in each quadrant of the visual field (superior-nasal, inferior-nasal, superior-temporal and inferior-temporal), number of points altered at different probability levels, and threshold values at each point of SAP. Results: In the normal and ocular hypertensive groups, only a few weak correlations were found between HRT and SAP parameters. The strength and number of significant correlations increased in the suspected glaucoma group. The glaucoma group had the strongest correlations, particularly between cup/disc ratio and rim/disc ratio with MD (r=0.479) and between rim area and PSD (r=0.444). Conclusions: Weak to moderate correlations were found between some ONH parameters obtained with the HRT and SAP results in the glaucoma group.

Keywords : Glaucoma; HRT; visual field; optic nerve head.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License