SciELO - Scientific Electronic Library Online

 
vol.44 issue3Gender bias in therapeutic effort: from research to health care author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Farmacia Hospitalaria

On-line version ISSN 2171-8695Print version ISSN 1130-6343

Abstract

MICHALEK, Christina  and  CARSON, Stacy L. Implementing barcode medication administration and smart infusion pumps is just the beginning of the safety journey to prevent administration errors. Farm Hosp. [online]. 2020, vol.44, n.3, pp.114-121.  Epub Oct 19, 2020. ISSN 2171-8695.  https://dx.doi.org/10.7399/fh.11410.

Introduction:

Healthcare-related technology has been widely accepted as a key patient safety solution to reduce adverse drug events by decreasing the risk of human error. The introduction of technology can enhance safety and support workflow; however, it does not eliminate all error types and may create new ones. Barcode medication administration and smart infusion pumps are two technologies utilized during medication administration to prevent medication errors before they reach the patient.

Objective:

This article reviewed different error types with barcode medication administration and smart infusion pumps and examined how these errors were able to occur while using the technology. Recommendations for preventing these types of errors were also discussed.

Conclusion:

Hospitals must understand the technology, how it is designed to work, which errors it is intended to prevent, as well as understand how it will change staff workflow. It is essential that metrics are set by hospital leadership and regularly monitored to ensure optimal use of these technologies. It is also important to identify and avoid workarounds which eliminate or diminish the safety benefits that the technology was designed to achieve. Front line staff feedback should be gathered on a periodic basis to understand any struggles with utilizing the technology. Leaders must also understand that even with full implementation of technology, medication errors may still occur.

Keywords : Barcode; Infusion pumps; Medication errors; Technology; Patient safety; Adverse drug events; Medication systems.

        · abstract in Spanish     · text in English | Spanish     · English ( pdf ) | Spanish ( pdf )