SciELO - Scientific Electronic Library Online

 
vol.15 issue1Blood recirculation during the haemodialysis session in the tunnelled catheter PalindromeTMRecipients of kidney transplants from donors in asystole and brain death: differences in nursing care author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Enfermería Nefrológica

On-line version ISSN 2255-3517Print version ISSN 2254-2884

Abstract

FERNANDEZ JIMENEZ, Antonio José et al. Permanent tunnelled central venous catheters for haemodialysis: study of recirculation and dialysis dose with normal and inverted lines. Enferm Nefrol [online]. 2012, vol.15, n.1, pp.28-38. ISSN 2255-3517.  https://dx.doi.org/10.4321/S2254-28842012000100005.

Introduction: Permanent tunnelled central venous catheters for haemodialysis frequently present a complication called the section effect, where the arterial branch collapses in the aspiration manoeuvres without offering resistance when pressed, making it necessary to invert the lines in order to carry out the treatment. The study focuses on the relationship between the anatomical position of the catheter tips using a chest X-ray and recirculation measured by Ultrasound Dilution, the Urea Reduction Ratio and Kt/V, determined both with lines in normal and inverted position and at pump flow rates of 250 and 300 ml/min. Material and method: Quasi-experimental intrasubject study with a duration of 18 months on n=28 catheters implanted in 25 patients undergoing Haemodialysis. Results:Recirculation: • Normal lines at 250 and 300 ml/min: 0.85 ± 2.41% and 1.23 ± 3.14%. • Inverted lines at 250 and 300 ml/min; 22.41 ± 12.12% and 24.93 ± 12.09%. • Urea Reduction Ratio: • Normal lines at 250 and 300 ml/min; 66.49 ± 8.62% and 70.55 ± 5.30%. • Inverted lines at 250 and 300 ml/min; 61.05 ± 8.34% and 62.34 ± 8.68%. • Kt/V: • Normal lines at 250 and 300 ml/min: 1.31 ± 0.30 and 1.46 ± 0.23%. • Inverted lines at 250 and 300 ml/min: 1.10 ± 0.21% and 1.19 ± 0.30%. Discussion: The Urea Reduction Ratios and Kt/V with inverted lines at both flow rates studied show suitable dialysis doses assuming recirculation of around 20%.

Keywords : Dialysis; Vascular access; Flow measurement; Cathether.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License