SciELO - Scientific Electronic Library Online

 
vol.17 issue1Analysis of the factors that influence the appearance of complications in and the survival of central venous catheters for haemodialysisHand hygiene perceptions and knowledge of healthcare workers in a Nephrology Unit: a comparative study author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Enfermería Nefrológica

On-line version ISSN 2255-3517Print version ISSN 2254-2884

Abstract

GONZALEZ MARTINEZ, Mª del Rocío et al. Study of the efficacy of a taurolidine and 4% citrate lock solution for haemodialysis catheters in the prevention of infection and thrombosis. Enferm Nefrol [online]. 2014, vol.17, n.1, pp.22-27. ISSN 2255-3517.  https://dx.doi.org/10.4321/S2254-28842014000100004.

The use of central catheters has increased significantly despite their greater morbi-mortality compared to AVF. The main complications are thrombosis, bacteriaemiasepsis, and limitation of dialysis efficacy, reducing quality of life for patients and increasing the healthcare cost. In our unit, 5% heparin sodium was previously used as lock solution and we currently use TauroLockTM Hep 500®, composed of (cyclo)-taurolidine (biocompatible antimicrobial agent) 4% citrate and heparin 500 UI/ml. Objective: To verify the efficacy of Taurolock in reducing the incidence of intraluminal colonization and thrombosis compared with 5% heparin sodium. Material and method: We carried out a longitudinal observational cohort study and we analysed intraluminal colonization, thrombosis, biofilm and use of antibiotherapy. Results: We observed an improvement in catheter permeability, a reduction in the use of urokinase, reduction in unipuncture sessions and in use of antibiotic. Conclusions: Our study shows that using a lock solution that contains taurolidine as an antimicrobial agent for haemodialysis catheters can significantly reduce the incidence of catheter-related sepsis. Taurolidine appears to be effective and safe and does not entail risks or side effects. The addition of 500 iu of heparin to the lock solution together with 4% citrate has reduced thrombotic events by reducing the use of fibrilolytics and eliminating completely the use of unipuncture, presenting an improvement in dialysis efficacy.

Keywords : central catheter; lock solution; infection; thrombosis; dialysis efficacy.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License