vol.27 número5Uso del mini nutritional assessment como herramienta de cribaje nutricional en la población mayor de 65 años en el ámbito hospitalario; conveniencia y factibilidadFactores de riesgo como pronóstico de padecer cáncer de mama en un estado de México índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Nutrición Hospitalaria

versión On-line ISSN 1699-5198versión impresa ISSN 0212-1611

Resumen

BALLESTEROS-POMAR, M.ª D. et al. Comparison of different body composition mesurements in severely obese patients in the clinical setting. Nutr. Hosp. [online]. 2012, vol.27, n.5, pp.1626-1630. ISSN 1699-5198.  https://dx.doi.org/10.3305/nh.2012.27.5.5989.

Background Aims: Body composition measurements seem to be not reliable enough in obese patients. Our aim was to compare single frequency-bioelectrical impedance (SF-BIA) analysis; foot-to-foot impedance meters (FFI) or upper body fat analysers (UBFA) and DXA (Dual-energy X-ray absorptiometry) in severely obese patients. Patients and methods: Cross-sectional study including 40 severely obese patients. Bioelectrical impedance was performed for SF-BIA (Holtain (H) and OMRON BF 500 (O500)), FFI (Tanita TBF-300 (T)) and UBFA (Omron BF 300 (O300)). DXA scans were performed using a Lunar iDXA. The data were analysed using Pearson's correlation and Bland Altman plots were also drawn to evaluate any agreements. Results: The percentage and total body fat values were 49.2% and 55.2 kg measured with DXA, 44.3%/53.4 kg with O300, 50.6%/58.3 kg with O500, 45.4%/55.4 kg with H and 49.1%/60.3 kg with T. The Holtain BIA showed the worst correlation with DXA for both %BF and FFM. Although the measurements of % body fat, fat mass and fat-free mass were significantly correlated with DXA, each method showed wide limits of agreement, although T was most closely correlated with DXA. Conclusion: Compared to DXA, FFI and UBFA could be useful for assessing body composition in severely obese people, although they appeared to underestimate %BF and FM and their limits of agreement were too wide.

Palabras clave : Obesity; Body composition; Nutritional assessment; Dual-energy X-ray absorptiometry; Bioelectrical impedance analysis.