SciELO - Scientific Electronic Library Online

 
vol.104 número10Estimaciones y proyecciones de incidencia, prevalencia y mortalidad del cáncer colorrectal en Aragón, España, para el periodo de 1998 a 2022 índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista Española de Enfermedades Digestivas

versión impresa ISSN 1130-0108

Resumen

BORDA, Fernando et al. Endoscopic localization of colorectal cancer: Study of its accuracy and possible error factors. Rev. esp. enferm. dig. [online]. 2012, vol.104, n.10, pp.512-517. ISSN 1130-0108.  https://dx.doi.org/10.4321/S1130-01082012001000002.

Introduction: accurate preoperative localization of colorectal cancer (CRC) is very important, with a wide range of published error rates. Aim: to determine accuracy of endoscopic localization of CRC in comparison with preoperative computed tomography (CT). To analyse variables that could be associated with a wrong endoscopic localization. Patients and methods: endoscopic and CT localization of a series of CRC without previous surgery were reviewed. We studied the concordance between endoscopic and radiologic localization against operative findings comparing accuracy of endoscopy and CT. We analysed the frequency of wrong endoscopic diagnoses with regard to a series of patient, endoscopy and tumor variables. Results: two hundred thirty seven CRC in 223 patients were studied. Concordance with surgical localization was: colonoscopy = 0.87 and CT = 0.69. Endoscopic localization accuracy was: 91.1%; CT: 76.2%: p = 0.00001; OR = 3.22 (1.82-5.72). Obstructive cancer presented a higher rate of wrong localization: 18 vs. 5.7% in non-obstructive tumors (p = 0.0034; OR = 3.65 (1.35-9.96). Endoscopic localization mistakes varied depending on tumor location, being more frequent in descending colon: 36.3%, p = 0.014; OR = 6.23 (1.38-26.87) and cecum: 23.1%, p = 0.007; OR = 3.92 (1.20-12.43). Conclusions: endoscopic accuracy for CRC localization was very high and significantly better than CT accuracy. Obstructive tumor and those located in the descending colon or cecum were associated with a significant increase of the error risk of CRC endoscopic localization.

Palabras clave : Colorectal cancer; Endoscopic localization; CT localization; Error factors.

        · resumen en Español     · texto en Español | Inglés     · Español ( pdf ) | Inglés ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons