SciELO - Scientific Electronic Library Online

 
vol.18 número56Seguridad en la administración de medicamentos: investigación sobre la práctica de enfermería y circunstancias de errores índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Enfermería Global

versión On-line ISSN 1695-6141

Resumen

FORTES ESCALONA, Nuria; FERNANDEZ DOMINGUEZ, Juana María; CRUZADO ALVAREZ, Concepción  y  GARCIA MATEZ, Susana. The use of venous catheters of average line in hospitalized patient. Enferm. glob. [online]. 2019, vol.18, n.56, pp.1-18.  Epub 23-Dic-2019. ISSN 1695-6141.  https://dx.doi.org/10.6018/eglobal.18.4.334891.

In the current context in which numerous alternatives have emerged in intravenous therapy, studies are needed on the different devices available to determine which is the most suitable system in each case. The midlines arise as an alternative to the use of peripheral venous catheters and central peripheral insertion catheters. The main objective of this study is to evaluate the use of midline catheters in hospitalized patients.

Method

Retrospective study of 1016 patients. We analyzed variables related to the mean time of catheter use, the incidence rate for each of the complications, the number of catheters removed and their causes.

Results

46.5% of the catheters were inserted in men (472). The average age was 65 years (SD 16.8), being the youngest of 14 and the oldest of 101 years. 40% of the catheters were channeled due to poor venous access of the patient (406), 42% for long intravenous treatment (427) and 18% for irritant treatment (183). Regarding the effectiveness of the catheters, the average time of use was 12.1 days (SD 9.4). The treatment was terminated by 854 patients, 704 (69.3%) by the end of treatment and 150 (14.8%) by death. 7.4% of patients presented complications (75). 4.4% (45) were removed due to malfunction of the catheter, 1% due to patient complications (10). 2% of the catheters were removed due to fever (20).

Conclusions

The middle line catheter is a venous access device with a low complication rate, it has a average residence time of around 12 days. It is an alternative to short peripheral catheters in patients with poor vein access and offers an alternative to frequent rotations in patients with antibiotic treatments longer than 7 days.

Palabras clave : venous access devices; midline catheter; midline.

        · resumen en Español     · texto en Español | Inglés     · Español ( pdf ) | Inglés ( pdf )