SciELO - Scientific Electronic Library Online

 
vol.23 número4Experiencia del cuidador entrenado en diálisis peritoneal durante la hospitalización del enfermo renal crónicoAnálisis de la calidad de vida del paciente en prediálisis y su relación con la dependencia para las actividades instrumentales de la vida diaria índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Enfermería Nefrológica

versión On-line ISSN 2255-3517versión impresa ISSN 2254-2884

Resumen

SANCHEZ-TOCINO, Mª Luz et al. Intra-method variability in the measurements of vascular access using the thermodilution technique: an enemy in follow-up programs?. Enferm Nefrol [online]. 2020, vol.23, n.4, pp.353-360.  Epub 25-Ene-2021. ISSN 2255-3517.  https://dx.doi.org/10.37551/s2254-28842020036.

Objective:

To analyze the impact of the intra-method variability of thermodilution (TD) in the prospective measurements of the access flow (QA) and the relationship with the first-generation monitoring parameters.

Method:

Prospective study. Two consecutive QA measurements (M1 and M2) and a 6-month follow-up (M3) were performed. Demographic data and first-generation follow-up parameters were collected.

Result:

112 arteriovenous fistulas (AVF) were analyzed. The median variability generated between M1 and M2 does not differ from the percentage of QA variation at 6 months (p=0.123). In 16.8% (14) of the patients the QA has decreased by more than 25% and in 28.9% (24) it increased by more than 25%. A slight tendency to increase the percentage of decrease in QA when the fistula flow was higher was evidenced (r=-0.229; p=0.006). On the other hand, a decrease in QA greater than 25% was not associated with a lower dose of dialysis (p=0.183), nor did it have a significant increase in dynamic venous pressure (p=0.823) or an increase in incidences during puncture (p=0.823).

Conclusions:

The presence of patients with an increase in flow greater than the intra-method variability, and the non-association between a decrease greater than 25% and changes in other follow-up parameters, raises suspicions about the presence of QA measurement errors. In relation to this, the combined use with first-generation methods is convenient, both to establish the baseline QA and to interpret the decreases in follow-up.

Palabras clave : vascular access; access flow; thermodilution; intra-method variability, monitoring.

        · resumen en Español     · texto en Español     · Español ( pdf )