vol.35 número5Características diferenciales de los pacientes con síndrome coronario agudo sin elevación del segmento ST con respecto a los que tienen elevación transitoria del segmento STPredicción de la utilidad clínica de la radiografía de tórax rutinaria en una unidad de cuidados intensivos de traumatología índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Medicina Intensiva

versão impressa ISSN 0210-5691

Resumo

RUIZ FERRON, F. et al. Intraabdominal and thoracic pressure in critically ill patients with suspected intraabdominal hypertension. Med. Intensiva [online]. 2011, vol.35, n.5, pp.274-279. ISSN 0210-5691.

Objective: To study the correlation between intraabdominal and intrathoracic pressure in patients with suspected intraabdominal hypertension. Design: A prospective, observational cohort study. Setting: Polyvalent intensive care unit of a University hospital. Patients: Twenty-seven medical-surgical patient dependent upon controlled mechanical ventilation due to acute respiratory failure and with several risk factors for intraabdominal hypertension (IAH). Main variables: Intraabdominal (IAP), esophageal (Peso) and airways pressure were measured under static (st) and dynamic (dyn) conditions. Respiratory system (Crs), lung (Cl) and chest wall compliance (Ccw) were calculated. Results: In 10 patients IAP>12mmHg (IAH, IAPst, 14±2 [12-21] mmHg), while in the rest the pressure proved normal (n=17; IAPst, 8±2 [3-11] mmHg). Peso st was 11±5 (2-27) and Peso dyn 7±4 (2-24) cmH2O. Depending on the presence or absence of IAH, Peso st was 9±4 vs 7±3cmH2O (p=0.2) and Peso dyn 6±2 vs 4±3cmH2O (p=0.3), respectively. The correlation between Peso st and dyn with IAPst was 0.5 (p=0.003) and 0.4 (p=0.03), respectively. The compliance components were decreased (Crs, 31±8; Cl, 52±22 and Ccw, 105±50ml/cmH2O); Ccw was significantly lower in patients with IAH (81±31 vs 118±55ml/cmH2O; p=0.02). The correlation coefficient between IAPst and Ccw was -0.7 (p<0.001), and -0.5 (p=0.002) with respect to Crs. Conclusions: A stiffer chest wall was observed in patients with IAH. In patients with risk factors for IAH, pressures in these compartments were highly variable.

Palavras-chave : Intraabdominal pressure; Chest wall compliance; Esophageal pressure; Mechanical ventilation; Abdominal compliance.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 