SciELO - Scientific Electronic Library Online

 
vol.43 número3Evaluación de tiempos quirúrgicos y transfusiones en pacientes quemados tratados con desbridamiento enzimáticoImplantes mamarios en España: resultados de encuesta a cirujanos plásticos índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Cirugía Plástica Ibero-Latinoamericana

versão On-line ISSN 1989-2055versão impressa ISSN 0376-7892

Resumo

CAMPILLO-CAMPANA, Ramón et al. Electrical burned hand: 5-year casuistry in Rio Hortega University Hospital, Valladolid, Spain. Cir. plást. iberolatinoam. [online]. 2017, vol.43, n.3, pp.231-237. ISSN 1989-2055.  https://dx.doi.org/10.4321/s0376-78922017000400003.

Background and Objective

High voltage burn patients usually produce important distal limb injuries. Among challenges o to be faced there are the important destruction of deep tissues, the progress or late identification of tissue injuries, the vascular lesions that difficult the reconstruction and infections.

Our aim is to expose the cases dealt with and the experience gained for the first 5 years of our Burn Unit in Universitary Hospital Rio Hortega in Valladolid, Spain.

Methods

We present a 6 patients series with 8 upper limb injuries because of high voltage burns who were treated in our Burn Unit. We detail the epidemiological and reconstructive technique data and the timing in each case. We also detail the physiological disturbances of these patients.

Results

Eight flaps to reconstruct the 6 upper limbs and 2 amputations in the middle of forearm were needed. We used 6 free flaps, 1 local flap and 1 distant flap. Cutaneous/fasciocutaneous flaps and muscular flaps were used 6 and 2 times respectively and 100% of the patients presented high levels of creatine phosphokinase (CPK) because of muscular damage, 2 of them needed renal replacement therapy.

Conclusions

In order to achieve limb reconstruction after high voltage injuries, plastic surgeons have to use all the techniques, from skin grafts to free flaps, going through skin substitutes. However amputations and neurological alterations are frequent in these patients.

Palavras-chave : Burns; Hand; Electric burns; High voltage burns.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )