SciELO - Scientific Electronic Library Online

 
vol.109 número10Pancreatic enzyme replacement therapy in cystic fibrosis: dose, variability and coefficient of fat absorption índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista Española de Enfermedades Digestivas

versão impressa ISSN 1130-0108

Resumo

BERNARDES, Carlos et al. Direct percutaneous endoscopic jejunostomy using single-balloon enteroscopy without fluoroscopy: a case series. Rev. esp. enferm. dig. [online]. 2017, vol.109, n.10, pp.679-683. ISSN 1130-0108.  https://dx.doi.org/10.17235/reed.2017.4717/2016.

Background: Direct percutaneous endoscopic jejunostomy (DPEJ) is a useful method to provide enteral nutrition to individuals when gastric feeding is not possible or contraindicated. The aim of this study was to analyze the efficacy and safety of DPEJ tube placement with the Gauderer-Ponsky technique by the pull method, using single-balloon enteroscopy (SBE) without fluoroscopy. Methods: This is a retrospective analysis of patients undergoing SBE for DPEJ placement in a referral hospital between January 2010 and March 2016. Technical success, clinical success and procedure related complications were recorded. Results: Twenty-three patients were included (17 males, median age 71 years, range 37-93 years). The most frequent indications for DPEJ were gastroesophageal cancer (n = 10) and neurological disease (n = 8). Eighty-seven percent of the patients had a contraindication to percutaneous endoscopic gastrostomy (PEG) and PEG was unsuccessful in the remaining patients. The technical success rate was 83% (19/23), transillumination was not possible in three patients and an accidental exteriorization of the bumper resulting in a jejunal perforation occurred in one patient. The clinical success was 100% (19/19). The median follow-up was five months (range 1-35 months). Apart from the case of jejunal perforation and the two cases of accidental exteriorization, there were no other complications during follow-up. The 6-month survival was 65.8% and the 1-year survival was 49.3%. Conclusion: DPEJ can be carried out successfully via SBE without fluoroscopy with a low rate of significant adverse events. Although, leaving the overtube in place during the bumper pulling can be useful for distal jejunal loops, it can be safely removed in proximal loops to minimize complications.

Palavras-chave : Jejunostomy; Direct percutaneous endoscopic jejunostomy; Enteroscopy; Single balloon enteroscopy; Enteral feeding.

        · texto em Inglês     · Inglês ( pdf )