SciELO - Scientific Electronic Library Online

 
vol.110 número4Réplica: Tumores quísticos neuroendocrinos de páncreas. Un reto diagnósticoLesión de Dieulafoy en divertículo duodenal. Una causa infrecuente de HDA índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista Española de Enfermedades Digestivas

versão impressa ISSN 1130-0108

Rev. esp. enferm. dig. vol.110 no.4 Madrid Abr. 2018

https://dx.doi.org/10.17235/reed.2018.5411/2017 

LETTERS TO THE EDITOR

Late migration of a metal stent after EUS-drainage of a pancreatic pseudocyst abscess

Belén Maldonado-Pérez1  , María-Fernanda Guerra-Veloz1  , Rafael Romero-Castro1 

1Unidad de Gestión Clínica de Aparato Digestivo. Hospital Universitario Virgen Macarena. Sevilla, España

Key words:  Drainage; Endoscopic ultrasound; Self-expanding metal stent; Migration

Dear Editor,

Endoscopic ultrasound (EUS)-guided drainage of pancreatic collections has replaced surgery as the first line of treatment due to its accuracy and safety profile 1,2. A higher success rate and fewer adverse events have been observed using fully covered metal stents for drainage 3,4. However, complications of EUS-guided drainage can occur in 1-18% of cases, the most frequent being acute bleeding, perforation, post-procedure infection and stent migration 5.

Case report

A 61-year-old female patient with a history of hypertension and obesity was admitted due to acute biliary pancreatitis. Abdominal computed tomography (CT) on admission showed necrosis greater than 75% and peripancreatic collections. The evolution was torpid, with an abscess collection in the tail of the pancreas. An EUS-guided drainage was performed and a fully covered lumen-apposing metal stent (Hanarosten(r); 12 mm diameter/4 cm length) was deployed with a 10F plastic double pigtail (Cook Medical(r), Baeswiler; Germany) inserted alongside.

Another 10F plastic double pigtail was inserted during another endoscopic session 19 days later (Fig. 1A). The patient underwent a progressive clinical, analytical and radiological improvement and was eventually discharged. Eight weeks later, an abdominal magnetic resonance imaging (MRI) showed complete resolution of the collection. Gastroscopy was performed to remove the stents, without visualizing them. An abdominal CT showed that the stents had lodged in the descending colon lumen, producing an increase in the pericolic fat (Fig. 1B), without signs of perforation. A colonoscopy with a pneumatic dilation up to 13.5 mm was required for their successful removal.

Fig. 1 A. EUS-guided drainage of the pancreatic collection. B. Abdominal CT showing the migrated stents in the descending colon. 

Bibliografía

1. Fusaroli P, Jenssen C, Hocke M, et al. EFSUMB Guidelines on Interventional Ultrasound (INVUS). Part V - EUS-Guided Therapeutic Interventions (short version). Ultraschall Med 2016;37(4):412-20. DOI: 10.1055/s-0035-1553742 [ Links ]

2. Itoi T, Binmoeller KF, Shah J, et al. Clinical evaluation of a novel lumen-apposing metal stent for endosonography-guided pancreatic pseudocyst and gallbladder drainage (with videos). Gastrointest Endosc 2012;75(4):870-6. DOI: 10.1016/j.gie.2011.10.020 [ Links ]

3. Tyberg A, Karia K, Gabr M, et al. Management of pancreatic fluid collections: a comprehensive review of the literature. World J Gastroenterol 2016;22(7):2256-70. DOI: 10.3748/wjg.v22.i7.2256 [ Links ]

4. Weilert F, Binmoeller KF, Shah JN, et al. Endoscopic ultrasound-guided drainage of pancreatic fluid collections with indeterminate adherence using temporary covered metal stents. Endoscopy 2012;44(8):780-3. DOI: 10.1055/s-0032-1309839 [ Links ]

5. Vilmann AS, Menachery J, Tang S-J, et al. Endosonography guided management of pancreatic fluid collections. World J Gastroenterol 2015;21(41):11842-53. DOI: 10.3748/wjg.v21.i41.11842 [ Links ]