SciELO - Scientific Electronic Library Online

 
vol.14 número2Factores sociológicos y calidad de vida relacionada con la salud en pacientes en hemodiálisisEficacia de un programa de entrenamiento intradiálisis de fuerza-resistencia en combinación con electroestimulación neuromuscular: mejora en la capacidad funcional, fuerza, y calidad de vida índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista de la Sociedad Española de Enfermería Nefrológica

versão impressa ISSN 1139-1375

Resumo

MARTINEZ ARANDA, Mª Amor et al. Efficacy of the use of bioconnectors for central catheters in haemodialysis. Rev Soc Esp Enferm Nefrol [online]. 2011, vol.14, n.2, pp.106-111. ISSN 1139-1375.

Tunnelled catheters (TC) are the vascular access used in haemodialysis (HD) for a very high percentage of patients. The use of TC is associated to two fundamental problems: dysfunction and infections. According to the guidelines established by the Spanish Nephrology Society (SEN), the use of luer-lock catheters is recommended in HD patients. On the market there are also bioconnectors, which are mechanically and microbiologically sealed devices. The advantage they offer is better handling of the catheter lumen when changed once a week. A study was carried out at our centre analysing two consecutive periods in a sample of 14 patients with CT. In the first period the conventional connection protocol was followed and in the second TEGO bioconnectors were used. Arterial and venous blood pressure was measured, blood flows, Kt, Kt/v and bacteraemia rate. No significant differences were obtained in these parameters with the use of TEGO devices compared to conventional use. We may conclude that the use of TEGO locks does not affect the dialytic parameters. However, we should consider the handling of any type of device as secondary in the prevention of bacteraemia, as it has been proved that universal aseptic measures are what achieve a very low bacteraemia rate.

Palavras-chave : Catheter; Bioconnector; Bacteraemia; Haemodialysis.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons