SciELO - Scientific Electronic Library Online

 
vol.10 número24Valoración de los conocimientos del cuidador principal sobre úlceras de presiónRol educativo del profesional de enfermería hacia los familiares de pacientes esquizofrénicos índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Enfermería Global

versão On-line ISSN 1695-6141

Resumo

SIMARRO BLASCO, J.A. et al. Comparative study of invasive blood pressure versus non-invasive blood pressure. Enferm. glob. [online]. 2011, vol.10, n.24. ISSN 1695-6141.  https://dx.doi.org/10.4321/S1695-61412011000400006.

In clinical practice, blood pressure is an important parameter in patient critic hemodynamic valuation. There are two ways of measuring: Invasive Pressure (IP) and Non Invasive Pressure (NIP). As objectives, we set ourselves the task of comparing the difference between both forms of measurement, assessing the possible differences by arterial location, age and sex, assessing the influence of mechanical ventilation, inotropic drugs and casework in invasive blood pressure difference (IP) and non invasive arterial pressure (NIP). We sought to identify its clinical significance and estimate the reliability of the NIP. We conducted a descriptive, longitudinal and comparative study between March and December 2008. Sex, age and arterial location (hemi-body and artery) were analyzed. We have included patients with artery with optimal curve and calibration at the time of measurement in decubitus. NIP was taken in both arms at an interval of five minutes, and IP was recorded at the same time. Analysis was with SPSS 15.0. The difference was analyzed in 109 patients with statistically significant differences in any scanned parameters. Under discussion and conclusions we propose that the differences found are not clinically significant and therefore the IP and the NIP are reliable in optimal calibration state.

Palavras-chave : Intensive care; determination of blood pressure; effect of drugs; nursing; blood pressure; artificial respiration; systolic pressure and diastolic pressure.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons