SciELO - Scientific Electronic Library Online

 
vol.18 número56Segurança na administração de medicamentos: Investigação sobre a prática de enfermagem e circunstâncias de erros índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Enfermería Global

versão On-line ISSN 1695-6141

Resumo

FORTES ESCALONA, Nuria; FERNANDEZ DOMINGUEZ, Juana María; CRUZADO ALVAREZ, Concepción  e  GARCIA MATEZ, Susana. The use of venous catheters of average line in hospitalized patient. Enferm. glob. [online]. 2019, vol.18, n.56, pp.1-18.  Epub 23-Dez-2019. ISSN 1695-6141.  https://dx.doi.org/10.6018/eglobal.18.4.334891.

In the current context in which numerous alternatives have emerged in intravenous therapy, studies are needed on the different devices available to determine which is the most suitable system in each case. The midlines arise as an alternative to the use of peripheral venous catheters and central peripheral insertion catheters. The main objective of this study is to evaluate the use of midline catheters in hospitalized patients.

Method

Retrospective study of 1016 patients. We analyzed variables related to the mean time of catheter use, the incidence rate for each of the complications, the number of catheters removed and their causes.

Results

46.5% of the catheters were inserted in men (472). The average age was 65 years (SD 16.8), being the youngest of 14 and the oldest of 101 years. 40% of the catheters were channeled due to poor venous access of the patient (406), 42% for long intravenous treatment (427) and 18% for irritant treatment (183). Regarding the effectiveness of the catheters, the average time of use was 12.1 days (SD 9.4). The treatment was terminated by 854 patients, 704 (69.3%) by the end of treatment and 150 (14.8%) by death. 7.4% of patients presented complications (75). 4.4% (45) were removed due to malfunction of the catheter, 1% due to patient complications (10). 2% of the catheters were removed due to fever (20).

Conclusions

The middle line catheter is a venous access device with a low complication rate, it has a average residence time of around 12 days. It is an alternative to short peripheral catheters in patients with poor vein access and offers an alternative to frequent rotations in patients with antibiotic treatments longer than 7 days.

Palavras-chave : venous access devices; midline catheter; midline.

        · resumo em Espanhol     · texto em Espanhol | Inglês     · Inglês ( pdf ) | Espanhol ( pdf )