SciELO - Scientific Electronic Library Online

 
vol.78 número2¿Penaliza el tipo de suelo en la prueba de agilidad-velocidad de las FFAA?Absceso tubo-ovárico por granulicatella adiacens. Descripción de un caso índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Sanidad Militar

versão impressa ISSN 1887-8571

Resumo

CARBAJO-OTERO, A et al. Biofilms in military food facilities. Comparison of rapid surveillance and verification techniques. Sanid. Mil. [online]. 2022, vol.78, n.2, pp.89-94.  Epub 20-Jan-2023. ISSN 1887-8571.  https://dx.doi.org/10.4321/s1887-85712022000200006.

Introduction:

Biofilm-forming pathogens increase the risk of biological food contamination in food industries, thus it is necessary to quantify and qualify the dangers present in them.

Objective:

To demonstrate the presence of bacterial biofilms on the work surfaces of military food facilities using different rapid hygienic control techniques.

Materials and methods:

An amount of 550 samples were analyzed among 10 military food facilities: Each one had 5 sampling points (n = 50) and in each of them 11 samples were obtainded on a surface of 100 cm2 to assess the presence of biofilms and to establish the correlation between different analytical techniques: determination of adenosin triphosphate (ATP) using 3M Clean-Trace ™ NG3 luminometer, protein residue titration with Clean-Trace ™ Surface Protein Plus swabs, mesophilic aerobic microorganism (AC) counts using TEMPO® and Petrifilm ™ system, and visualization of biofilms using enzymatic reaction with Biofinder®.

Results:

A statistically significant correlation (p <0.05) was found between ATP determinations and the presence of biofilms and protein residues. Linearity with statistical significance (R2 0.422, p <0.05) was also found between ATP and AC count by TEMPO®. Correlation and concordance between AC counts were observed using the TEMPO® system and through Petrifilm ™ (intraclass correlation coefficient 0.463, 95% CI: 0.179-0.673, p <0.05). At no sampling point (SP) were pathogenic bacteria detected.

Conclusion:

Combining quick techniques should be considered in surveillance procedures of Hazard Analysis and Critical Control Points (HACCP).

Palavras-chave : biofilm; cross contamination; ATP; cleaning and disinfection; HACCP.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )