SciELO - Scientific Electronic Library Online

 
vol.31 número6Compra de alimentos de proximidad en los comedores escolares de Andalucía, Canarias y Principado de AsturiasCondiciones de trabajo en consultorios adyacentes a farmacias privadas en Ciudad de México: perspectiva del personal médico índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Gaceta Sanitaria

versão impressa ISSN 0213-9111

Resumo

GUZMAN RUIZ, Óscar; PEREZ LAZARO, Juan José  e  RUIZ LOPEZ, Pedro. Performance and optimisation of a trigger tool for the detection of adverse events in hospitalised adult patients. Gac Sanit [online]. 2017, vol.31, n.6, pp.453-458.  Epub 30-Nov-2020. ISSN 0213-9111.  https://dx.doi.org/10.1016/j.gaceta.2017.01.014.

Objective:

To characterise the performance of the triggers used in the detection of adverse events (AE) of hospitalised adult patients and to define a simplified panel of triggers to facilitate the detection of AE.

Method:

Cross-sectional study of charts of patients from a service of internal medicine to detect EA through systematic review of the charts and identification of triggers (clinical event often related to AE), determining if there was AE as the context in which it appeared the trigger. Once the EA was detected, we proceeded to the characterization of the triggers that detected it. Logistic regression was applied to select the triggers with greater AE detection capability.

Results:

A total of 291 charts were reviewed, with a total of 562 triggers in 103 patients, of which 163 were involved in detecting an AE. The triggers that detected the most AE were “A.1. Pressure ulcer” (9.82%), “B.5. Laxative or enema” (8.59%), “A.8. Agitation” (8.59%), “A.9. Over-sedation” (7.98%), “A.7. Haemorrhage” (6.75%) and “B.4. Antipsychotic” (6.75%). A simplified model was obtained using logistic regression, and included the variable “Number of drugs” and the triggers “Over-sedation”, “Urinary catheterisation”, “Readmission in 30 days”, “Laxative or enema” and “Abrupt medication stop”. This model showed a probability of 81% to correctly classify charts with EA or without EA (p <0.001; 95% confidence interval: 0.763-0.871).

Conclusions:

A high number of triggers were associated with AE. The summary model is capable of detecting a large amount of AE, with a minimum of elements.

Palavras-chave : Patient safety; Adverse event; Medical error; Adverse effect.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )