SciELO - Scientific Electronic Library Online

 
vol.85 número5Idoneidad de tratamiento en sospechosos de glaucoma: Estudio de concordancia con el grupo de estudio RAND índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Archivos de la Sociedad Española de Oftalmología

versão impressa ISSN 0365-6691

Resumo

SANCHEZ-DALMAU, B.; LLORENC, V.; ORTIZ, S.  e  MARTINEZ, L.. Comparison of three optical coherence tomography devices, one time-domain and two fourier-domain, for the estimation of the retinal nerve fibre layer thickness. Arch Soc Esp Oftalmol [online]. 2010, vol.85, n.5, pp.165-173. ISSN 0365-6691.

Purpose: To assess agreement between one system of time-domain optical coherence tomography (OCT) (Stratus) and two systems of fourier-domain OCT (Cirrus and 3D OCT-1000) for the measurement of the retinal nerve fibre layer thickness (RNFL). Methods: Fifty eyes from 25 patients with neuro-ophthalmological disorders of the afferent visual pathway were included. A triple RNFL thickness OCT examination with Stratus, Cirrus and 3D OCT-1000 was performed on both eyes of every patient, on the same day and by the same technician. The average RNFL thickness by quadrants and clock sectors were compared with the Lin´s concordance correlation coefficient (CCC) and Bland-Altman plots. Results: The average RNFL thickness, the temporal and nasal quadrants and corresponding clock sectors, was higher by 3D OCT-1000 (mean 90.02 microns), nevertheless, RNFL thickness of the superior and inferior quadrants and corresponding clock hours was higher when measured by Stratus device. The CCC agreement between Stratus and Cirrus was high (0.820), between Stratus and 3D OCT-1000 was moderate (mean 0.573) and between Cirrus and 3D OCT-1000 was moderate with a mean of 0.564 but too low in the nasal and temporal quadrants (0.362 and 0.347 respectively). Conclusions: The RNFL thickness measurements by Stratus, Cirrus and 3D OCT-1000 OCT are not equivalent. Although the agreement between Stratus and Cirrus was high, it was too low between 3D OCT-1000 and Stratus or Cirrus.

Palavras-chave : Optical coherence tomography; OCT; Time-Domain OCT; Fourier-Domain OCT; Retina; Optic nerve; Retinal nerve fibre layer RNFL; Optic neuropathy.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons