My SciELO
Services on Demand
Journal
Article
Indicators
Cited by SciELO
Access statistics
Related links
Cited by Google
Similars in SciELO
Similars in Google
Share
Actas Urológicas Españolas
Print version ISSN 0210-4806
Abstract
ROMERO MAROTO, J. et al. TVA and TOA: New adjustable mesh for the treatment of female stress incontinence. Preliminaries resulted. Actas Urol Esp [online]. 2006, vol.30, n.2, pp.186-194. ISSN 0210-4806.
Objectives: Evaluation of a new mesh for incontinence (TVA/TOA) which enables the degree of tension applied during surgery to be readjusted at the post-operative stage. Patients and Method: 62 patients treated with the TVA mesh and monitored over a 14-month period (SD 7.8, range 6-38). In 33 patients (53%) some other pelvic prolapse was corrected. Evaluation was carried out by clinical report, examination of bladder full of 250 saline solution, flowmetry and urinary residue. 40 patients filled in 4 quality of life questionnaires (QoL; ICIQ-SF; PGI-S; PGI-I). Results: 42 patients were found to be objectively continent in the post-operative evaluation. Of these, it was necessary to reduce tension in 7 cases (11%) due to urinary obstruction (flow<10 ml/sec and/or residue). The tension of the mesh was tightened in 20 patients (32%) due to continue with a certain degree of incontinence. All patients were discharged as continent and with no residue. In the last revision, 58 patients (93%) proved to be objectively continent and 4 (6.5%) showed a notable improvement in their incontinence. The QMAX is 19.8 ml/sec (SD 9.8). The mictional urgency had disappeared or improved in 32 of the patients who had this prior to operation (76%) and had appeared in 3 of the patients who didnt (15%). The clinical report showed a high level of consensus with the ICIQ-SF survey (Kappa = 0.89) regarding stress incontinence, diminishing clearly (Kappa=0.13) when urge incontinence was taken into account. 34 (85%) patients scored over 95 out of 110 in the QoL. 30 (75%) scored less than 6 in ICIQ-SF. 32 (80%) showed a perception of normality and 4 (10%) slight illness in the PGI-S. In the PGI-I 29 (72.5%) were much better and 11 (27.5%) quite a lot better. A relation exists between urgency and dismissed quality of life. Conclusion: With the TVA (trans-vaginal adjustable) mesh it is possible to adjust the tension originally applied during surgery at the post-operative stage, so that any defects or excesses can be corrected.
Keywords : Urinary incontinence; Surgery; Adjustable sling; Questionnaire; Quality of life; Maxim flow.