SciELO - Scientific Electronic Library Online

 
vol.35 número5El factor de crecimiento fibroblástico está asociado con el índice de masa ventricular izquierda, anemia y niveles bajos de saturación de la transferrinaCaracterísticas clínicas, evolución y pronóstico de la nefropatía membranosa idiopática en función de la presencia de anticuerpos contra el receptor tipo M de la fosfolipasa A2 índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Nefrología (Madrid)

versão On-line ISSN 1989-2284versão impressa ISSN 0211-6995

Resumo

MADUELL, Francisco et al. Optimization of dialysate flow in on-line hemodiafiltration. Nefrología (Madr.) [online]. 2015, vol.35, n.5, pp.473-478. ISSN 1989-2284.  https://dx.doi.org/10.1016/j.nefro.2015.06.019.

Introduction: Currently, on-line hemodiafiltration (HDF-OL) is the most effective technique. Several randomized studies and meta-analyses have shown a reduced mortality and a direct association with convective volume has been reported. At present, it has not been established if an increased dialysate flow (Qd) results in improved results in terms of convective and depurative efficiency. We aim at assessing the effects of Qd variations on convective volume and its depurative capacity in patients on HDF-OL. Material and methods: A total of 59 patients (45 men and 14 women) from a HDF-OL programme in which a monitor 5008 Cordiax with self-replacement was used, were enrolled. Patients were assessed in 5 sessions with post-dilutional HDF-OL, using helixone-based dialyzers, with only Qd being changed (300, 400, 500, 600 and 700 ml/min). Serum levels of urea (60 Da), creatinine (113 Da), ß2-microglobulin (11,800 Da), myoglobin (17,200 Da) and a1-microglobulin (33,000 Da) were measured at the beginning and at the end of each session, in order to estimate the percent reduction of such solutes. Results: An increased dialysate volume per session was observed, from 117.9 ± 6.4 L with Qd 300 ml/min to 232.4 ± 12 L with Qd 700 ml/min. No changes were found in replacement volume or convective volume. Regarding diffusion, Qd increase was associated to a significantly increased dialysis dose, with an increased Kt from 68 ± 6.9 L with Qd 300 ml/min to 75.5 ± 7.3 L with Qd 700 ml/min (p < 0,001), and a gradually increased percent reduction in urea associated to increased Qd with significantly lower levels being found with Qd 300 ml/min. No changes were found in other measured substances. Conclusion: Qd variations in HDF-OL do not change convective volume. A higher Qd was associated to a slightly increased urea clearance with no change being observed for medium and large molecules. Qd optimisation to the minimal level assuring an adequate dialysis dose and allowing water and dialysate use to be rationalised should be recommended.

Palavras-chave : Dialysate flow; On-line hemodiafiltration; Efficacy; Convective volume.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons