SciELO - Scientific Electronic Library Online

 
vol.31 issue2High-protein diet induces oxidative stress in rat brain: protective action of high-intensity exercise against lipid peroxidationEffect of alpha lipoic acid on the blood cell count and iron kinetics in hypertensive patients author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Nutrición Hospitalaria

On-line version ISSN 1699-5198Print version ISSN 0212-1611

Abstract

RUIZ, Jonatan R.; ORTEGA, Francisco B  and  CASTRO-PINERO, José. Validity and reliability of the 1/4 mile run-walk test in physically active children and adolescents. Nutr. Hosp. [online]. 2015, vol.31, n.2, pp.875-882. ISSN 1699-5198.  https://dx.doi.org/10.3305/nh.2015.31.2.7789.

We investigated the criterion-related validity and the reliability of the 1/4 mile run-walk test (MrWt) in children and adolescents. A total of 86 children (n=42 girls) completed a maximal graded treadmill test using a gas analyzer and the 1/4MRW test. We investigated the test-retest reliability of the 1/4MRWT in a different group of children and adolescents (n=995, n=418 girls). The 1/4MRWT time, sex, and BMI significantly contributed to predict measured VO2peak (R2= 0.32). There was no systematic bias in the cross-validation group (P>0.1). The root mean sum of squared errors (RMSE) and the percentage error were 6.9 ml/kg/min and 17.7%, respectively, and the accurate prediction (i.e. the percentage of estimations within ±4.5 ml/kg/min of VO2peak) was 48.8%. The reliability analysis showed that the mean inter-trial difference ranged from 0.6 seconds in children aged 6-11 years to 1.3 seconds in adolescents aged 12-17 years (all P<0.001). In conclusion, the present study shows that the criterion-related validity of the 1/4MRW test is relatively low in the sample of children and adolescents studied. Beside the statistical significance, the reliability of the 1/4MRWT was considered acceptable, i.e. mean difference between tests ranged from half second to one second

Keywords : 1/4 mile run-walk test; Cardiorespiratory fitness; Validity; Reliability; Children; Adolescents.

        · abstract in Spanish     · text in English     · English ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License