SciELO - Scientific Electronic Library Online

 
vol.77 número12Queratitis difusa de la interfaseDesarrollo de un sistema automático de discriminación del campo visual glaucomatoso basado en un clasificador Neuro-Fuzzy índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

Compartir


Archivos de la Sociedad Española de Oftalmología

versión impresa ISSN 0365-6691

Resumen

VILLARRUBIA CUADRADO, A et al. Intraocular phakic lens ZSAL-4 for high myopia correction. Arch Soc Esp Oftalmol [online]. 2002, vol.77, n.12, pp.661-667. ISSN 0365-6691.

Purpose: To evaluate the effectiveness, safety and predictability of the phakic intraocular lens (IOL) ZSAL-4 for correction of high myopia. Methods: In this retrospective study 28 IOL in 19 patientes were implanted. The following data were recorded, preoperatively, one week, one month, 3, 6 and 12 months postoperatively: spherical equivalent (SE), astigmatism, uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), endothelial cell density (CD), coefficient of variation (CV) and intraocular pressure (IOP). We performed LASIK in 3 eyes to correct a residual refractive defect. Results: The mean age was 29.7 S.D. 5.77 years and the mean following 7.62 S.D. 7.29 months. Six months postoperatively, the preoperative SE of -14.91 S.D. 2.88 was reduced to -1.29 S.D. 0.53; the BCVA varied from 0.56 S.D. 0.16 to 0.58 S.D. 0.12; the CD changed from 2670 S.D. 252 cells/mm2 to 2344 S.D. 262. The CV showed stability. The UCVA six months postoperatively was 0.39 S.D. 0.15. No eyes lost any line of BCVA; during the first month 63% of the eyes won 2 or more lines. The efficacy index was 0.83 S.D. 0.24 one month postoperatively and 0.63 S.D. 0.32 one year postoperatively; the safety index was 1.44 D.S. 0.34 and 1.30 S.D. 0.35 respectively. One IOL was explanted the second day due to pupilary blockage; 7 eyes had transient high IOP; 2 eyes developed pupilary ovalization and in 4 cases the IOL suffered some degree of rotation. One eye presented a flat retinal detachment one year postoperatively but with no other complications. The 3 eyes submitted to LASIK presented 0.8 of BCVA the third month after LASIK. Conclusions: ZSAL-4 IOL implantation is an effective and safe procedure with an acceptable predictability which, in some cases, could be improved with LASIK.

Palabras clave : High myopia; ZSAL-4; phakic lens.

        · resumen en Español     · texto en Español

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons