SciELO - Scientific Electronic Library Online

 
vol.81 issue9Variation of central corneal thickness in diabetic patients as detected by ultrasonic pachymetryDiagnostic ability of stratus optical coherence tomography (OCT) in pre-perimetric glaucoma diagnosis author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Archivos de la Sociedad Española de Oftalmología

Print version ISSN 0365-6691

Abstract

SIMON, G.. Trabeculoplasty with two different lasers in cats, monkeys and humans: A scanning electron microscopy study. Arch Soc Esp Oftalmol [online]. 2006, vol.81, n.9, pp.527-536. ISSN 0365-6691.

Purpose: To study the structural changes induced by trabeculoplasty with two different lasers (Ti-Sph and argon) and observe the differences between four trabecular meshwork models. Materials and methods: Four different trabecular meshwork (TM) models were used from cats, monkeys, and humans. This study was performed on fresh cadaver eyes («ex vivo») except for the cat in which this study was performed «in vivo». The morphology of the trabecular meshwork was observed by scanning electron microscope (40/100X) after being treated with argon (0.1s/pulse, 600 to 1,000mW, 50µ spot size) and Ti-Sph (7µsg/pulse, 25 to 110mJ,175µm of spot size). The study on cats allowed assessment of the induced effect after 24 hours, and 4 weeks after the treatment on the TM. Typical clinical trabeculoplasty parameters were used for both lasers during this study. Results: The models used in this study were found to be adequate for trabeculoplasty. They exhibited a deep anterior chamber and an accessible TM. The argon laser induced significant changes in the TM in all models studied. The cat model demonstrated TM repair response one month after treatment. For Ti-Sph, high levels of energy (>100mJ) were required to induce significant structural changes in the TM. Conclusion: The IOP reduction effect by argon trabeculoplasty (600/1,000mW) induced structural shrinkage of the collagen in the TM via thermal effects. The Ti-Sph laser works through non-structural mechanisms. At clinical levels (lower than 80mJ), Ti-Sph does not show evidence of TM changes.

Keywords : Scanning electron microscopy; trabeculoplasty; Ti-Sapphire; argon; trabecular meshwork.

        · abstract in Spanish     · text in Spanish     · English ( pdf ) | Spanish ( pdf )

 