SciELO - Scientific Electronic Library Online

 
vol.86 número4Estudio de la función lagrimal y la superficie conjuntival en pacientes diabéticosRituximab en queratitis ulcerativa periférica asociada a artritis reumatoide índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Archivos de la Sociedad Española de Oftalmología

versão impressa ISSN 0365-6691

Resumo

GONZALEZ DE LA ROSA, M. et al. Comparing the ranges of defect measured with standard white on white and Pulsar perimetries. Arch Soc Esp Oftalmol [online]. 2011, vol.86, n.4, pp.113-117. ISSN 0365-6691.

Objectives: Normal thresholds on Pulsar perimetry fall faster than those of standard perimetry in the peripheral visual field. Two related studies were performed. Firstly, the frequency distributions of glaucoma defects on standard automated perimetry (SAP) and the relationship of the centre and periphery (Study A) were studied first, followed by an attempt to establish the limits of pulsar perimetry (Study B). Material and method: A: frequency of defects was calculated in 78.663 SAP perimetries (G1-TOP, Octopus 1-2-3, Haag-Streit). Study B: 204 eyes with mean defect (MD-SAP) lower than 9dB were examined 8.92±4.19 times with SAP (TOP-32, Octopus 311) and temporal modulation perimetry (T30W, Pulsar Perimeter, Haag-Streit). Results: Study A: 50.7% of the SAP examinations showed MD values lower than 9dB and 32.7% bellow 6dB. The MD correlation of the central 20o with the MD of the most peripheral points was r=0.933. Study B: in cases with MD-TOP-32 lower than 6dB, SAP had the maximum possibility of detecting defect in 0.02% of points and Pulsar in 0.29%. In subjects with MD-TOP-32 between 6 and 9dB frequencies were 0.38% in SAP and 3.5% in Pulsar (5.1% for eccentricities higher than 20o). Conclusions: Pulsar allows detecting defects, without range limitations, in the initial half of SAP frequencies expected on glaucoma patients. In order to study the progression of deeper defects the examination should focus on the central points, where the dynamic range of both systems is more equivalent.

Palavras-chave : Perimetry; Visual field; Glaucoma; Threshold; Dynamic range.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons