SciELO - Scientific Electronic Library Online

 
vol.84 número1Morbilidad psíquica, existencia de diagnóstico y consumo de psicofármacos: Diferencias por comunidades autónomas según la encuesta nacional de salud de 2006Mortalidad por cáncer de mama: evolución en España y sus comunidades autónomas durante el período 1980-2005 índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista Española de Salud Pública

versão On-line ISSN 2173-9110versão impressa ISSN 1135-5727

Resumo

HORMANSDORFER, Cindy et al. Comparison of Current Methods of Prenatal Screening for Down Syndrome. Rev. Esp. Salud Publica [online]. 2010, vol.84, n.1, pp.43-51. ISSN 2173-9110.

Background: In Spain all pregnant women aged 35 years and older are offered genetic examination through invasive testing in order to detect fetal trisomy 21 cases (maternal age indication (MAI)). In the last decade five distinct software programs utilizing the "first trimester screening (FTS)" were developed. The objective of this study is to compare the test performance of the different screening methods in order to detect the best current approach. Methods: 7.736 complete first trimester screenings, including the fetal outcome, were realized between 31.08.1999 and 24.05.2007 in three prenatal health centres in Hannover, Peine, and Wolfenbüttel in Germany. Out of these 6.508 cases were analyzed retrospectively in this study. Maternal age was determined and risk calculation with the software programs PIA, PRC, JOY, AFS and AFS-3D was executed. Results: The MAI reached a sensitivity of 57.50%, detecting only 23 out of 40 trisomy 21 cases, and a false positive rate of 21.60%. In comparison, all risk calculation programs obtained superior results, attaining a sensitivity between 90.00% (AFS) and 92.50% (PIA, PRC, JOY, AFS-3D) and a false positive rate between 2.64% (AFS-3D) and 7.87% (PIA). The difference was highly significant (p<0.0001) Conclusions: The MAI is obsolete and inadequate in comparison with the risk calculation software, out of which all obtained test performances within the range of comparable international publications. Among these programs, JOY, AFS, and AFS-3D obtained the best results.

Palavras-chave : Aneuploidy; Down syndrome; First Trimester pregnancy; Trisomy 21; Maternal age.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons